LBI-39055
19
Data General 386SX/25A (Acer)
The set-up program is started by pressing
<Ctrl><Alt><Esc> during the boot process. COM1 is
disabled by selecting the "
System Security Setup
"
and then setting "
Serial Port1 Control
" to
"
[Disable]
". Press <Esc> twice to save the change and
reboot.
Compaq 386S
This PC's set-up program is not used to disable the
built-in COM1 port. Instead, COM1 is disabled by setting
the main board's DIP switch SW2 positions 4 and 5 both
"ON". Refer to the PC's documentation for additional
details.
SOFTWARE INSTALLATION AND
UPGRADES
As previously stated, all C3
Maestro application
software is installed on the PC's hard disk drive at the
factory. Refer to Ericsson GE document SRN-1000-xx
which is included with a software upgrade package if a re-
installation or an upgrade is necessary.
FILE DIRECTORIES AND CONTENTS
Table 12 specifies PC file directories and files directly
applicable to the C3 Maestro console. The MS-DOS file
directory and its files are not shown. Also, other utility files
not listed in the table may exist in the utility directory
which are not essential to the operation of the C3 Maestro
application program.
TABLE 12 - C3 MAESTRO
PC FILE DIRECTORIES AND FILES
ROOT
DIRECTORY
(C:\)
CONSOLE
DIRECTORY
(C:\CONSOLE)
UTILITY
DIRECTORY
(C:\UTIL)
AUTOEXEC.BAT
CONFIG.SYS
COMMAND.COM*
IO.SYS*
MSDOS.SYS*
AUXIO.DAT
CONFIG.DAT
CONKEY.COM
CONSOLE.EXE
EDITOR.EXE
ENGLISH.DAT
ENTITY.DAT
FONT33.DAT
NORWEGAN.DAT
PHONE.DAT
SETUPS.DAT
CTEST.EXE
* MS-DOS V3.3 or greater. IO.SYS and MSDOS.SYS are
hidden files.
AUTOEXEC.BAT File Contents
Contents of the AUTOEXEC.BAT file located in the
root directory (C:\) are as follows. Changes are not
recommended:
@ECHO OFF
PATH=C:\DOS;C:\UTIL
PROMPT $P$G
CD\CONSOLE
CONKEY
CONSOLE
CONFIG.SYS File Contents
Contents of the CONFIG.SYS file located in the root
directory (C:\) are as
follows. Changes are not
recommended:
FILES=20
BUFFERS=40
DEVICE=C:\DOS\ANSI.SYS
NOTE
Earlier consoles used a "
BUFFERS=25
" setting.
EDITOR PROGRAM
If necessary, the Editor program (EDITOR.EXE) can
be used to change one or more or the following parameters
(non-inclusive list):
•
Logic Board Interrupt (IRQ)
•
COM1 Serial Port Baud Rate
•
Set-Up Titles
•
Call Director ID
•
Boom/Gooseneck Mic Presence (version 2.x and
previous only)
Except for the Call Director ID parameter, these
parameters cannot be changed via the CEC/IMC Manager
(MOM PC).
NOTE
CEC/IMC Manager (MOM PC) version 2.x (and
earlier) also did not provide support for Call
Director ID; this parameter also had to be set via
the Editor program.