must be initialized as described in the following section
before dispatch operations can be performed.

DATABASE INITIALIZATION

When the console initializes from a cold start, all of

the following sections should be performed to insure proper
operation. All console databases are  initialized via
commands from the CEC/IMC Manager (MOM PC). See
the  CEC/IMC Manager operations guide LBI-38911
(version 2.x) or LBI-39024 (version 3.x) for additional
details.

Basically, except for sending console configurations,

all  procedures presented in this section assume all
CEC/IMC console configurations are complete as described
in the CEC/IMC Digital Audio Switch Installation, Set-Up
And Troubleshooting
 maintenance manual, LBI-38938. See
"STEP 6 - CONSOLE CONFIGURATION" in LBI-
38938 for details.

Console User Profile Configuration

From the CEC/IMC Manager, user profile data is sent

only to the targeted console. When a target console receives
user profile data from the CEC/IMC Manager it will send
an acknowledgment to the CEC/IMC Manager. Send user
profile data to the console as follows:

1.  From the CEC/IMC Manager's "

CEC/IMC MOM

Options

" main menu, select the "

Console

Configuration

" option. This will display the

console configuration sub-menu.

2.  From this sub-menu, select the "

Console User

Profile

" option. This will display the

"

CONSOLE USER PROFILE

CONFIGURATION

" screen.

3. Verify 

the "

CONSOLE

" number matches the CIM's

console number as defined by the  CIM's DIP
switches.

4. Verify 

the  "

Unit ID

" number does not  conflict

with that of any other console or radio ID number
in the system.

5. Select 

the  correct "

Setup

" and then make any

required modification(s) to the configuration. If
required, save the new configuration.

6.  Press the <F7> function key  to send the Console

User Profile configuration to the console.

7.  When the "

User Profile Successfully

Written...

" message is displayed, return to the

CEC/IMC Manager' main menu. If an "

Unable

to Write User Profile...

" message

appears or no message appears after ten  (10)
seconds, the  CIM 

may not  be properly installed

and/or configured. Check Controller Board
installation and DIP  switch settings. A "

User

Profile Successfully Written...

"

message must be received before continuing with
the next procedure.

System Manager Database Uploads

System  Manager databases contain all system

information for all defined entities (units, groups, sites).
These databases can be downloaded by the console by
requesting database uploads from the CEC/IMC Manager.
Since this data is broadcast to all consoles in the CEC/IMC
system, if possible, all consoles should be on-line when this
upload occurs. This avoids having to repeat the process for
other consoles at a later time.

1.  From the CEC/IMC Manager's "

CEC/IMC MOM

Options

" main menu, select the "

System

Manager Data

" option. This will display a sub-

menu.

2. Select 

"

Upload From System Manager

".

3. From the "

SYSTEM MANAGER UPLOAD

STATUS

" screen, select <F1> then <F8> for a full

unit upload. After the upload is complete, exit the
screen by pressing <Esc>.

4. From the "

SYSTEM MANAGER UPLOAD

STATUS

" screen, select <F2> then <F8> for a full

group upload. After the upload is complete, exit
the screen by pressing <Esc>.

5. From the "

SYSTEM MANAGER UPLOAD

STATUS

" screen, select <F6> then <F8> for a full

site upload. After the upload is complete, exit the
screen by pressing <Esc>.

6.  From the "

System Manager Data

" sub-menu,

select the "

Upload From MOM PC

" option.

7.  From the "

MOM PC BASED SYSTEM MANAGER

UPLOAD STATUS

" screen, select <F3> then

<F8> for a full conventional channel upload. After
the upload is complete, exit the screen by pressing
<Esc>.

8.  From the "

MOM PC BASED SYSTEM MANAGER

UPLOAD STATUS

" screen, select <F5> then

<F8> for a full console upload. After the upload is
complete, exit the screen by pressing <Esc>.

Содержание C3 MAESTRO LBI-39055

Страница 1: ...c Audio ALC Enable Disable DIP Switch 6 I O Board 6 INTERCONNECTING THE EQUIPMENT 6 CEC IMC INTERCONNECTIONS 7 Control Data Link 7 Remote Console Interconnections Via A 4 Wire Modem 8 Audio Links 9 PE...

Страница 2: ...TION 21 Console User Profile Configuration 21 System Manager Database Uploads 21 Console Privilege Lists 22 Saving Database Information 22 SYSTEM TESTS 22 LOW LEVEL TESTS 22 Recommended Test Equipment...

Страница 3: ...ibed NOTE C3 Maestro application software version 3 0x requires C3 Maestro Logic Board firmware version 3 02 or later CEC IMC Controller and Audio Board firmware version 3 0x or later and CEC IMC Mana...

Страница 4: ...sole system BOARD SET UP IMPORTANT NOTE Unless otherwise noted all procedures in this manual should be performed in the order presented LOGIC BOARD Normally the Logic Board is configured correctly and...

Страница 5: ...stro console system ships from the factory If the console system is ordered with multiple unselect speakers 2 or 3 or with the Call Director patch option two Audio PA Boards are installed DIP switches...

Страница 6: ...h SW1 on the Audio Matrix Board is used to independently enable or disable each microphone s automatic level control ALC circuit The switch has four 4 positions one for each mic that may be connected...

Страница 7: ...d in most all installations it is used for co located console interconnections RS 232 has poorer noise performance than RS 422 and therefore it should never be used for cable runs more than 50 feet in...

Страница 8: ...g 3002 data grade specifications must be employed between the CEC IMC and the C3 Maestro in a remote console installation Figure 8B shows typical control data interconnections for a remote console ins...

Страница 9: ...recommended TABLE 5 CONSOLE TO CEC IMC BALANCED LINE AUDIO INTERCONNECTIONS STANDARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER AUDIO PA BOARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER TO FROM CEC IMC 1 none n...

Страница 10: ...LBI 39055 10 Figure 8A CEC IMC To C3 Maestro Interconnections Co Located...

Страница 11: ...LBI 39055 11 Figure 8B CEC IMC To C3 Maestro Interconnections Remote And Or RS 232...

Страница 12: ...ole s application program Connect the standard PC keyboard to the PC in accordance with the manufacturer s instructions Video Display Monitor Interconnect the video display monitor s video cable to th...

Страница 13: ...gooseneck microphone option CRMC3F or equivalent may be connected to the Audio Tower Mount the microphone in accordance with the instructions supplied With the gooseneck microphone the supplied male D...

Страница 14: ...ector to the respective female DB 9 connector on the I O Board Volume Controller Box if used If the console system is equipped with speakers the Volume Controller Box must be used Typically it is loca...

Страница 15: ...in LBI 39062 for audio signal output level specifications Figure 10 I O Board Recorder Terminal Block Pin Out Pager Input if used Pager connections are also located on a terminal block on the I O Boar...

Страница 16: ...e considered LINE C and LINE D respectively Figure 7 shows modular jack locations LINE C if used for a second unselect speaker connects to CEC IMC CIM channel line 3 Call Director LINE D connects to C...

Страница 17: ...into the CD This handset overrides all audio connections to the Audio Tower The operator talks directly to the phone via the handset instead of using the console s headset or mic speaker Dry contact...

Страница 18: ...C CMOS SET UP PROGRAM C3 Maestro software is factory installed on the PC s hard disk drive and the software is configured properly for standard installations Therefore during a typical console configu...

Страница 19: ...BLE 12 C3 MAESTRO PC FILE DIRECTORIES AND FILES ROOT DIRECTORY C CONSOLE DIRECTORY C CONSOLE UTILITY DIRECTORY C UTIL AUTOEXEC BAT CONFIG SYS COMMAND COM IO SYS MSDOS SYS AUXIO DAT CONFIG DAT CONKEY C...

Страница 20: ...number that is only used for Call Director telephone patch operations The default value for this ID is zero 0 no Call Director Valid Call Director ID range is 1 16382 The zero setting should not be c...

Страница 21: ...ser Profile configuration to the console 7 When the User Profile Successfully Written message is displayed return to the CEC IMC Manager main menu If an Unable to Write User Profile message appears or...

Страница 22: ...ity to control the Audio Tower s audio matrix circuitry It also verifies the line coupling circuitry and the speaker amplifier circuitry Cross point audio matrix switches are controlled opened and clo...

Страница 23: ...Speaker B If not send the LINE B input to the SPKR B output by typing the following command F2 6641 Enter Adjust the unselect speaker Speaker B volume knob up and down and verify the volume changes T...

Страница 24: ...nd the CEC IMC The procedures assume all equipment has been interconnected and set up in accordance with the previous instructions presented in this manual Control Data Link The C3 Maestro console and...

Отзывы: