PERSONAL COMPUTERS

In most cases, the Personal Computer (PC) used with

the C3 Maestro console is delivered with the Logic Board
installed, its hard disk drive formatted and MS-DOS
operating system software installed on the hard disk drive.
The C3 Maestro application software is also installed on
the drive.

Hardware

Table 1 lists the PCs approved for  use with a C3

Maestro console system. Use  of an unapproved computer
will void the console system's warranty and support
services. Subsequent to the  printing of this manual,
additional PCs not listed in the table may be approved.

TABLE 1 

−−

 APPROVED PERSONAL COMPUTERS

FOR USE WITH THE C3 MAESTRO

MANUFACTURER

MODEL NO. OR TYPE

Hewlett-Packard

Vectra 25N

Hewlett-Packard

486SX/25

Data General

Dasher 386SX/16

Data General

Dasher 386SX/20

Data General*

386/25A

Compaq

386S

* Manufactured for Data General by Acer; all plastic case.

Operating System Software

The PC will have either MS-DOS version 3.3, 5.x or

6.x installed on its hard drive. MS-DOS 5.x  or 6.x is
preferred. All Data General and Hewlett-Packard
computers ship from the factory with either MS-DOS 5.x or
6.x.  MS-DOS  4.x  is not approved for use with the  C3
Maestro console system.

BOARD SET-UP

IMPORTANT NOTE

Unless otherwise noted, all procedures in this
manual should be performed in the order
presented.

LOGIC BOARD

Normally, the Logic Board is configured correctly and

installed inside the PC before the  C3 Maestro console
system is delivered to the customer. The following
information is presented for reference only.

DIP Switches

SW1 

−−

 Dual-Port Address DIP Switch

All positions of DIP switch SW1 on the Logic Board

should be in the "ON" or "CLOSED" position. This sets the
base address of the  dual-port RAM chip on the board to
D000:0000 (hex). SW1 switch should never be configured
in any other way. Figure 2 shows the "0000" setting.

Figure 2 

−−

 Logic Board SW1 Factory Setting

SW2 

−−

 Interrupt (IRQ) DIP Switch

DIP switch SW2 on the Logic Board sets the  board's

interrupt request (IRQ) line. It should be set with position 1
"ON" or "CLOSED" and  all other positions "OFF" or
"OPEN". This sets the interrupt to seven (IRQ7). Normally,
SW2 should not be configured in any other way. Figure 3
shows the setting. This setting is not a binary-code decimal
equivalent representation of the interrupt number; the
switch simply provides a single-pole four-throw switch
function using four single-pole single-throw DIP switches.

Logic Boards previous to Rev. A were not  equipped

with SW2; the interrupt was hardwired as IRQ7.

Figure 3 

−−

 Logic Board SW2 Factory Setting

ON

1

2

3

4

ON

1

2

3

4

Содержание C3 MAESTRO LBI-39055

Страница 1: ...c Audio ALC Enable Disable DIP Switch 6 I O Board 6 INTERCONNECTING THE EQUIPMENT 6 CEC IMC INTERCONNECTIONS 7 Control Data Link 7 Remote Console Interconnections Via A 4 Wire Modem 8 Audio Links 9 PE...

Страница 2: ...TION 21 Console User Profile Configuration 21 System Manager Database Uploads 21 Console Privilege Lists 22 Saving Database Information 22 SYSTEM TESTS 22 LOW LEVEL TESTS 22 Recommended Test Equipment...

Страница 3: ...ibed NOTE C3 Maestro application software version 3 0x requires C3 Maestro Logic Board firmware version 3 02 or later CEC IMC Controller and Audio Board firmware version 3 0x or later and CEC IMC Mana...

Страница 4: ...sole system BOARD SET UP IMPORTANT NOTE Unless otherwise noted all procedures in this manual should be performed in the order presented LOGIC BOARD Normally the Logic Board is configured correctly and...

Страница 5: ...stro console system ships from the factory If the console system is ordered with multiple unselect speakers 2 or 3 or with the Call Director patch option two Audio PA Boards are installed DIP switches...

Страница 6: ...h SW1 on the Audio Matrix Board is used to independently enable or disable each microphone s automatic level control ALC circuit The switch has four 4 positions one for each mic that may be connected...

Страница 7: ...d in most all installations it is used for co located console interconnections RS 232 has poorer noise performance than RS 422 and therefore it should never be used for cable runs more than 50 feet in...

Страница 8: ...g 3002 data grade specifications must be employed between the CEC IMC and the C3 Maestro in a remote console installation Figure 8B shows typical control data interconnections for a remote console ins...

Страница 9: ...recommended TABLE 5 CONSOLE TO CEC IMC BALANCED LINE AUDIO INTERCONNECTIONS STANDARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER AUDIO PA BOARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER TO FROM CEC IMC 1 none n...

Страница 10: ...LBI 39055 10 Figure 8A CEC IMC To C3 Maestro Interconnections Co Located...

Страница 11: ...LBI 39055 11 Figure 8B CEC IMC To C3 Maestro Interconnections Remote And Or RS 232...

Страница 12: ...ole s application program Connect the standard PC keyboard to the PC in accordance with the manufacturer s instructions Video Display Monitor Interconnect the video display monitor s video cable to th...

Страница 13: ...gooseneck microphone option CRMC3F or equivalent may be connected to the Audio Tower Mount the microphone in accordance with the instructions supplied With the gooseneck microphone the supplied male D...

Страница 14: ...ector to the respective female DB 9 connector on the I O Board Volume Controller Box if used If the console system is equipped with speakers the Volume Controller Box must be used Typically it is loca...

Страница 15: ...in LBI 39062 for audio signal output level specifications Figure 10 I O Board Recorder Terminal Block Pin Out Pager Input if used Pager connections are also located on a terminal block on the I O Boar...

Страница 16: ...e considered LINE C and LINE D respectively Figure 7 shows modular jack locations LINE C if used for a second unselect speaker connects to CEC IMC CIM channel line 3 Call Director LINE D connects to C...

Страница 17: ...into the CD This handset overrides all audio connections to the Audio Tower The operator talks directly to the phone via the handset instead of using the console s headset or mic speaker Dry contact...

Страница 18: ...C CMOS SET UP PROGRAM C3 Maestro software is factory installed on the PC s hard disk drive and the software is configured properly for standard installations Therefore during a typical console configu...

Страница 19: ...BLE 12 C3 MAESTRO PC FILE DIRECTORIES AND FILES ROOT DIRECTORY C CONSOLE DIRECTORY C CONSOLE UTILITY DIRECTORY C UTIL AUTOEXEC BAT CONFIG SYS COMMAND COM IO SYS MSDOS SYS AUXIO DAT CONFIG DAT CONKEY C...

Страница 20: ...number that is only used for Call Director telephone patch operations The default value for this ID is zero 0 no Call Director Valid Call Director ID range is 1 16382 The zero setting should not be c...

Страница 21: ...ser Profile configuration to the console 7 When the User Profile Successfully Written message is displayed return to the CEC IMC Manager main menu If an Unable to Write User Profile message appears or...

Страница 22: ...ity to control the Audio Tower s audio matrix circuitry It also verifies the line coupling circuitry and the speaker amplifier circuitry Cross point audio matrix switches are controlled opened and clo...

Страница 23: ...Speaker B If not send the LINE B input to the SPKR B output by typing the following command F2 6641 Enter Adjust the unselect speaker Speaker B volume knob up and down and verify the volume changes T...

Страница 24: ...nd the CEC IMC The procedures assume all equipment has been interconnected and set up in accordance with the previous instructions presented in this manual Control Data Link The C3 Maestro console and...