![Ericsson 1553-FGC 101 1010 Uen A Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/ericsson/1553-fgc-101-1010-uen-a/1553-fgc-101-1010-uen-a_handbook_2423331069.webp)
Output Data Rate
The system is designed to support a maximum output data rate of 120 Mbps.
The bit rate of each output transport stream can be individually controlled with a resolution of 1 kps.
Transport Stream Parameters
The output rate of all transport streams is derived from the Base Unit's
27 MHz clock
. This can be locked to any 27 MHz or 10 MHz
clock provided by an option card, or can free run. This means that it can be locked to an option card's video input, or locked to the
external sync input on the External Sync Module.
A transport stream has the following parameters associated with it.
Output Enable
On
IP Output is enabled if the IP destination can be
resolved
Dest. IP Address
aaa.bbb.ccc.ddd
The destination IP address
Source IP Port
0 to 65335
[default = 5500]
Source IP Port number
Dest. IP Port
0 to 65335
[default = 5500]
Destination IP Port number
Type Of Service
0 to 255
[Default = 4]
ToS value for inclusion in the IP header
Time To Live
0 to 240
[ Default = 15]
TTL value for inclusion in the IP header
Encapsulation Type
UDP [Default]
UDP encapsulation of TS packets
RTP
UDP/RTP encapsulation of RTP Packets
RTP/FEC Column
UDP/RTP encapsulation of RTP Packets with added
one-dimensional FEC
RTP/FEC Column and Row
UDP/RTP encapsulation of RTP Packets with added
two-dimensional FEC
Parameter
Values
Description
Transport Stream
Name
Text string of up to 32
characters
The name of the transport stream, which is only used to
identify it on the user interface(s)
SI Level
Off
No SI Tables are generated
PAT/PMT only [Default]
Only PAT/PMT tables are generated
PAT/PMT/CAT/SDT
Only PAT/PMT/CAT and SDT tables are generated.
PMT PID
32 to 8190
[Default 32]
The PID assigned to the PMT of this transport stream
TS Bit rate
0.1 to 216.00 Mbps
Transport stream rate in Mbps to a resolution of 10 kbps
PCR On Separate PID
Enable
PCR information is carried on its own PID
Disable [Default]
A separate PCR PID is not generated
PCR PID
32 to 8190
The PID to be used for the PCR if PCR on separate PID is
enabled
Table of Services
A list of the services that are included in the transport stream
© Ericsson AB 2011. All rights reserved