![Ericsson 1553-FGC 101 1010 Uen A Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/ericsson/1553-fgc-101-1010-uen-a/1553-fgc-101-1010-uen-a_handbook_2423331153.webp)
ASI Option Module Alarms
The following table lists the alarm and failure identifiers generated by the ASI option module.
metadata
Module
Slot n
0
000A00B5
655541
input
stop encoding on loss.
Name
Module
Slot
Port
ID (hex)
ID (dec)
Type
Description
Over Temperature
Warning
ASI IO
Module
Slot 1
0
000E0001
917505
internal
Failure to take action may cause
permanent damage to the chassis. Please
check the fans are working correctly, and
that th eambient temperature is not
excessive.
Over Temperature
ASI IO
Module
Slot 1
0
000E0002
917506
internal
Failure to take action may cause
permanent damage to the chassis. Please
switch off and refer to Customer Support.
Invalid Parameter
ASI IO
Module
Slot 1
0
000E0003
917507
internal
Invalid Parameter received by the ASI IO
Module. Please see Video Encoder status
for a more detailed description of the error.
Module Error
ASI IO
Module
Slot 1
0
000E0004
917508
internal
Option Card Error. Please see log for a
more detailed description of the error.
Power On Self
Test Failure
ASI IO
Module
Slot 1
0
000E0006
917510
internal
At least one start-up test has failed.
Problems may be experienced with the
normal operation of the chassis.
Internal HW
Information
ASI IO
Module
Slot 1
0
000E0007
917511
internal
HW reported an unexpected status value.
This does not effect normal operation of
the chassis.
Option Card Build
Version Mismatch
ASI IO
Module
Slot 1
0
000E0008
917512
internal
The software on this option card is not an
officially released version.
ASI Output Error
ASI IO
Module
Slot 1
0
00110020
1114144
internal
An error has occurred in ASI Output 1. See
the log for more details.
© Ericsson AB 2011. All rights reserved
© Ericsson AB 2011. All rights reserved
Page 153 of 153