Note:
In this release the ASI outputs are mirrored - the same transport stream is transmitted from both outputs.
Two 75 Ω female BNC input connectors are also available but are not supported in this release.
ASI Option Module Rear Panel
Getting Started
Before any communication can be made with the unit the Control IP address needs to be configured. The topics in this section will
guide you through the process.
Setting the IP address
Describes how to set the required IP Address from the Front Panel.
IP address Ranges
This topic shows a table of allocated IP addresses adhering to the RFC3330 range of restrictions .
Manual configuration via the web pages
The unit has been designed to be configured and controlled by nCC, however a web interface is available to configure the unit
(primarily for use during development).
Initial Configuration within nCC
Describes the initial setup of the unit via nCC.
Setting the Required IP Address from the Front Panel
Power on the unit
Wait for initialisation to complete (approximately 1.5 minutes, depending on the number of options fitted in the chassis).
Press the Right arrow pushbutton until the IP address is displayed, press edit and then use the up/down/right/left arrow
pushbuttons to set the required IP address
- Right/left pushbuttons will move the cursor between characters
- Up/down pushbuttons will increase/decrease the number selected by the cursor
Press save to store the new IP address.
Continue and set the subnet mask and gateway address in the same way using the down pushbutton to reach each
parameter.
NOTE : IP Address range 192.168.10.x (subnet 255.255.255.0) is used for internal unit communications, so
should not be used for external communications.
Refer to Operation and Control >
Front Panel
for more details describing Front Panel features.
NOTE : As with previous encoder models, a pushbutton is illuminated when there is functionality available. If a
pushbutton is not illuminated, pressing it will have no effect.