A
technical earth terminal
is located at the rear panel of the chassis.
IP Output Transport Stream
The following parameters are controllable for each IP Output transport stream for each output port or ports depending on the
redundancy mode that is selected:
Control Ethernet Specification
Overview
The system has two Ethernet control ports, that support IEEE 802.3 100BASE-TX and 1000BASE-T Ethernet protocols. The Control
ports are accessible via RJ-45 connectors on the rear panel of the chassis and support IEEE 802.3u auto-negotiation and parallel
detection. Also, the ports support Auto-MDIX.
IP Parameters
It is possible to configure the following IP parameters for the Control Port
Parameter
Description/Range
Comment
Source IP Address
aaa.bbb.ccc.ddd
Source IP address
Subnet Mask
aaa.bbb.ccc.ddd
Source Subnet address
Source UDP Port
0 to 65535
Source IP Port Number
Destination IP Address
aaa.bbb.ccc.ddd
Destination IP address
Destination UDP Port
0 to 65535
Destination IP Port Number
Time To Live
0 to 240
TTL value for inclusion in the IP header
Type Of Service
0 to 255
ToS value for inclusion in the IP header
Item
Specification
Connector type
RJ-45 (100/1000 Base T)
Connector designation
Ctrl 1/2
Pin outs
(Unused pins are not connected)
Pin 1 - Rx/Tx A(+)
Pin 2 - Rx/Tx A (-)
Pin 3 - Rx/Tx B (+)
Pin 4 - Rx/Tx C (+)
Pin 5 - Rx/Tx C (-)
Pin 6 - Rx/Tx B (-)
Pin 7 - Rx/Tx D (+)
Pin 8 - Rx/Tx D (-)
Parameter
Description
IP Address
xxx.xxx.xxx.xxx (Ipv4)
Network Mask
xxx.xxx.xxx.xxx (Ipv4)
Gateway Address
xxx.xxx.xxx.xxx (Ipv4)
© Ericsson AB 2011. All rights reserved
© Ericsson AB 2011. All rights reserved
Page 120 of 153
Cover
9/11/2012
file://C:\Users\ebriacl\AppData\Local\Temp\~hh7DF.htm