background image

SAMPLE  DRUM

Please follow the instructions for use of the Erica Synths module below, ‘cause 

only this will guarantee proper operation of the module and ensure warranty 

from Erica Synths. 

Water is lethal for most of the electric devices, unless they are made waterproof. This Erica Synths module is NOT intended for use in a humid or wet 

environment. No liquids or other conducting substances must get into the module. Should this happen, the module should be disconnected from mains 

power immediately, dried, examined and cleaned by a qualified technician. 

Transport the instrument carefully, never let it drop or fall over. Warranty does not apply to modules with visual damages.

Do not expose the module to temperatures above +50° C or below -20° C. If you have transported module in extreme low temperatures, leave it in 

room temperature for an hour before plugging it in.

The module has to be shipped in the original packaging only. Any module shipped to us for return, exchange and/or warranty repair has to be in its 

original packaging. All other deliveries will be rejected and returned to you. Make sure you keep the original packaging and technical documentation. 

This device complies to the EU guidelines and is manufactured RoHS conforming without use of lead, mercury, cadmium and chrome. Nevertheless, 

this device is special waste and disposal in household waste is not recommended.

You will find Erica Synths terms of warranty at 

www.ericasynths.lv

Items for return, exchange and/or warranty repair have to be sent to:

Erica Synths

Andrejostas Str. 43

Riga

Latvia

LV-1045

User manual by Girts Ozolins@Erica Synths.

Design by Ineta Briede@BLACK8.

Copying, distribution or any commercial use in any way is prohibited and needs the written permission by Erica Synths.

Specifications are subject to change without notice.

In case of any questions, feel free to contact us through www.ericasynths.lv or via e-mail [email protected]

Power off the Sample Drum. Copy the latest firmware file to the root directory of the 

SD card and insert the SD card in the module and power it on.

The module will automatically detect the latest firmware version on the SD card and 

compare it with the one installed.

Push the encoder A/DATA to initiate the firmware update procedure or push the 

encoder C to quit the firmware update. Only the firmware files will be replaced, all 

settings and samples on the SD card and in the module will remain unchanged.

Once the update is completed press the A encoder or power off the module and power 

it on again. Enjoy the great features of the latest firmware!

FIRMWARE 

UPDATE

SAFETY 

INSTRUCTIONS

Содержание Sample Drum

Страница 1: ...aneously Six encoders A F change their functions depending on the operation mode Encoder A always is the main select data encoder clicking encoder D will return to the previous menu page These are tri...

Страница 2: ...omptly to add the sample to the RAM of the module The sample will be uploaded on the releaseoftheencoder Touploadthesamplesfromthefolders clicktheencodertoopenthe folderandselectsamples Inordertoretur...

Страница 3: ...EandFtoselectstartpoint looppointandendpointofthesample payback Inloopmodetheplaybackwillstartattheselectedstartpoint playtotheendpoint andthencontinueloopingbetweenstartandlooppoints Pleasenotethatin...

Страница 4: ...PushtheencoderEtoresetsliceplaybacktothefirstslice IftheCVscaleissetto1V Octthefirst 32notesstartingfromC 0willplaythefirst32slices Nicetrickistoprepare1barlongloopsandsliceupthemto16slicesandthentri...

Страница 5: ...BACK Erespectively UsetheencoderD BACKtosetthepotentialRANGEoftheincomingaudiosignal meaning ifyourecordsamplesfromthemodularsynth settherange10V 10Vptpsignal ifyourecord samplesfromexternalsynthswit...

Страница 6: ...fectsarebypassed Eacheffecthasthreeparametersthatcanbecontrolledmanu allyviaencodersD BACK EandForviaCV iftheCVisassignedtotheeffectparameters see theCVassignmenu NB Forfiltereffectsyouneedtosetthedry...

Страница 7: ...ng RotatetheencoderCtomorphtheDecayshapefromexponential 50setting throughlinear 0setting tologarithmic 50setting Allenvelopesettingsaresavedwiththechannelinsteadofindividualsample Pleasereferto thePRO...

Страница 8: ...heendpoint SMP LOOP adjustthelooppoint AMPLITUDEPARAMETERS AMP ATTACK changetheattacktime AMP HOLD changetheholdtime AMP DECAY changethedecaytime AMP ATTACKSHAPE changetheshapeofattackfromLintoLog AMP...

Страница 9: ...rCtoselecttheparameter PushtheencoderCtoconfirm This is complete performance screen where two different samples are loaded in channel 1 and channel2 thesampleinthechannel1issplitin8slices thesampleint...

Страница 10: ...de while the other is playing but for doubleprojectstheplaybackwillbeinterruptedwhilethesampleswillload A new screen with the project naming will appear Use the encoder A DATA to navigate through the...

Страница 11: ...optionifenabledwillshowtheCVoffsetforsettingswhichhavetheCVcontrol enabled Intheoutputscreenyoucansettheoutputlevelsforachofthesided 1 2 andalsoseethe scopeofeachoutput Maximumsetting 100 setstheoutpu...

Страница 12: ...device complies to the EU guidelines and is manufactured RoHS conforming without use of lead mercury cadmium and chrome Nevertheless this device is special waste and disposal in household waste is not...

Отзывы: