background image

11/21

9

8

ii

i

14mm (9/16")

b

a

1x

1x

1x

EN

888-24-092-G-02 rev. H • 05/11

Adjustment

Release Brake to move riser.

Follow these instructions to tighten or loosen tension.

It is important that you adjust this product according to the weight of the mounted equipment as described in the following steps. Any time equipment is added or removed from this 
product, resulting in a change in the weight of the mounted load, you should repeat these adjustment steps to ensure safe and optimum operation.
Adjustments should move smoothly and easily through the full range of motion and stay where you set it. If adjustments are diffi

  cult and do not stay in the desired position, follow 

the instructions to loosen or tighten the tension to create a smooth, easy adjustment motion. Depending on your product and the adjustment, it may take several turns to notice a 
diff erence. 

Lift – Up and down

NOTE: Adjustment may require 40 - 60 
revolutions.

Loosen knob, tilt Display to desired 
position then retighten knob.

Tilt – Forward and Backward

Содержание StyleView SV32

Страница 1: ...sito De senaste versionerna av installationshandledningen och nedladdning av programvaran för StyleLink finns på 最新版ユーザインス トールガイ ドとスタイルリンクソフ トウェアは次のサイ トでダウンロードできます 请从下列地址获取最新版本的用户安装指南和 StyleLink 软件下载 사용자 설치 안내서 및 StyleLink 소프트웨어 다운로드는 다음 웹 사이트에서 제공하고 있습니다 A B 1 2 3 4 5 6 3x 1x 1x 1x 1x 1x 1x 2x 1x 2x 1x 4x M4 x 10mm 4x M4 x 10mm 1x 1x M4 x 8mm M4 x 5mm 14mm 9 16 6 1 8 m EN 888 24 092 G 02 rev H 05...

Страница 2: ...mérique de la classe A est conforme à la norme NMB 003 du Canada FCC Compliance Statement The cart has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and ca...

Страница 3: ...0 4 Drawers 9 compartments SV32 81226 Input 120VAC 60 Hz 5 1A Output 120VAC 60 Hz 400VA 300W The cart and power system are certified to UL 60601 and CAN CSA C22 2 601 1 M90 6 Drawers 6 compartments SV32 82211 SV32 83211 Input 230V 50 Hz 2 7A Output 230V 50 Hz 400VA 300W The cart and power system are compliant with EN 60601 1 1 Drawer 6 compartments SV32 82222 SV32 83222 Input 230V 50 Hz 2 7A Outpu...

Страница 4: ...o Eliminate Independent LCD Lift section 3 lbs 1 4 kg Worksurface 13 lbs 5 9 kg CPU Compartment CAUTION If the combined LCD and CPU weight is greater than 23 lbs 10 4 kg then the CPU must be mounted to the rear of the cart using the Universal CPU Holder accessory ordered separately see inset below 4 5 lbs 2 0 kg without insert 2 5 lbs 1 1 kg with insert Total weight capacity per drawer Weight Capa...

Страница 5: ... 1x 2x 1x EN 888 24 092 G 02 rev H 05 11 Set up Connect Keyboard and Mouse to USB Hub NOTE Bar Code Scanner should be connected directly to computer USB port DO NOT connect Bar Code Scanner to the USB Hub USB Type A USB Type A ...

Страница 6: ...d Moving Parts can Crush and Cut Raise monitor to top of vertical adustment BEFORE removing Failure to heed this warning may result in serious personal injury or property damage 822 310 With Independent LCD Lift 6 16 lbs 2 7 7 3 kg Without Independent LCD Lift 20 lbs 9 kg See How To Eliminate Independent LCD Lift section ...

Страница 7: ...ra Small Form Factor CPU s Center CPU in storage area USFF Ultra Small Form Factor Thin Client Route computer cables down opening in enclosure left or right side Route computer cables down opening in enclosure left or right side Place AC Power Adaptors in compartment Route power cable down along tower Power cables need to be 6 1 8 m long ...

Страница 8: ...8 21 d c 1x 1x e f a 5 EN 888 24 092 G 02 rev H 05 11 Set up ...

Страница 9: ...hes when charging power cord plugged into wall outlet Allow battery to continue charging until light stops flashing After light stops flashing it is OK to unplug the power cord from the wall You can use cart while charging Battery has less than 90 charge Battery has less than 70 charge Battery has less than 50 charge Battery has less than 30 charge Light is red and alarm beeps Plug in power cord a...

Страница 10: ...6 If computer still does not turn on contact Ergotron Customer Care Keyboard Light Keyboard Light will automatically turn off after 15 minutes if not manually turned off USBType A connection on computer Ethernet Crossover connection on computer NOTE these cables are factory connected to the USB Hub WARNING Fan must always be running when computer is on Operating computer without fan may lead to ov...

Страница 11: ... load you should repeat these adjustment steps to ensure safe and optimum operation Adjustments should move smoothly and easily through the full range of motion and stay where you set it If adjustments are difficult and do not stay in the desired position follow the instructions to loosen or tighten the tension to create a smooth easy adjustment motion Depending on your product and theadjustment i...

Страница 12: ...Lift 6 16 lbs 2 7 7 3 kg Without Independent LCD Lift 20 lbs 9 kg WARNING IMPACT HAZARD MOVING PARTS CAN CRUSH AND CUT DO NOT remove Stop Screw without monitor attached Doing so will cause monitor pivot to shoot up rapidly and may cause personal injury To Remove Monitor 1 Remove stop screw while monitor is attached 2 Lift monitor to highest postion 3 Remove monitor Failure to heed this warning may...

Страница 13: ...rawers will light 2 Simultaneously press 4 and 6 Numbers 4 and 6 will light green 3 Simultaneously press 4 and 6 again Numbers 4 and 6 will flash green 4 Simultaneously press 4 and 6 a third time All numbers will light green You have 10 seconds to enter a new User PIN 5 Input new 5 digit User PIN All numbers will flash green You can continue to enter 5 digit User PINs until finished After sitting ...

Страница 14: ...rs 1 Amp Fuse Turn power system off by holding down the AC Outlet Power button for 1 3 seconds Power light will shut off Turn off all mounted equipment Recommended Littelfuse 312001P Disconnect Power System from power source Before reseting circuit breakers contact Ergotron to determine cause of trip ...

Страница 15: ...batteries while cart is located in an oxygen rich or hazardous environment arcing may occur and cause combustion Replace first battery before removing second battery to reduce the risk of cables touching terminals and causing arcing Always replace both batteries Replace first battery before removing second battery Replace batteries with same Amp Hour rating batteries only Only Ergotron specified b...

Страница 16: ... Black Caution Connect Red before connecting Black Caution Remove Black before removing Red Red Red Black BATTERY LEAD Recycle battery or contact Ergotron for proper battery disposal guidelines Red Caution Connect Red before connecting Black Black Follow Battery Charge Discharge Initial Power on steps ...

Страница 17: ...g Disconnect Power System from power source Once battery has been charged to 100 turn power system off a Turn power system off by holding down the AC Outlet Power button for 1 3 seconds Power light will shut off b Turn both circuit breakers to OFF NOTICE Warranty on fully charged batteries left in an unused state for more than three 3 consecutive months is automatically void Warranty on fully disc...

Страница 18: ...ber charge battery fully 100 every day Maintenance Safety Color Symbol Signal Word Level of Hazard Red DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Orange WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Yellow CAUTION Indicates a potentially hazardous situation which i...

Страница 19: ...ower cord ground connection and any accessible metal parts on the cart although not mandatory the following test is recommended to be performed every two years using a calibrated medical device safety analyzer The procedure is as follows 1 Disconnect the cart from mains power unplug cart from the wall 2 Remove power from internal power system outlets by pressing the power button on the Power Syste...

Страница 20: ...erential mode 2 kV common mode Complies Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 seconds Complies Mains power quality should be that of a ...

Страница 21: ... mm 15 5 394 mm 1 8 46 mm 10 3 261 mm 4 102 mm 1 65 41 8 mm 16 8 427 mm 4 4 9 4 112 239 mm 24 2 44 2 614 1123 mm 47 4 67 4 1204 1712 mm 30 6 50 6 778 1285 mm 5 3 134 mm 4 4 112 mm 8 8 224 mm EN 888 24 092 G 02 rev H 05 11 Features Specifications When figuring dimensions include mounted accessories protruding cables and port replicators or docking stations CPU Compartment ...

Отзывы: