Sana comfort 150 and 250 REHA 

 

 

Article no.: 2.520064 rev.: b 

Page 12 of 24 

 

5

 

Safety notes 

5.1

 

Precautions during operation 

Before using the unit, make sure that the medical product consultant has conducted an introduction in 

regard to function and safety precautions. 

The unit should not be used if there are any doubts as to its being isolated from earth or the suitability of 

the power cable. 

The supplied power cable meets valid regulations for medical applications. 

The unit is not intended for use in wet rooms, outdoors or in areas where there is danger of explosion. 

Before its initial operation, the device must be adjusted using the base adjustors at the back to provide 

absolute stability.  

When the saddle is exchanged, make sure that the screws at the saddle are tightened hard enough so 

that the saddle cannot be moved on the saddle pipe.  

To move the handle bars and saddle, loosen the clamps and retighten them well afterwards. It is recom-

mended to position the clamps with the levers positioned vertically downward. Secure clamping is en-
sured when the handles are then again turned to this position during the adjustment procedure after 

every movement. 

The holding straps on the pedals must fit perfectly across the upper side of the shoe and be fastened with 

a Velcro strap.

 

5.2

 

Safety precautions when operating with other devices 

When several devices are coupled, there is a risk that the leakage currents may add up. 

Interface RS 232, which can be used for communication with other devices, is isolated to ensure the pa-

tient’s safety. 

External devices may only be connected with the interface cables supplied by ergosana. 

5.3

 

Maintenance safety precautions 

The device must be turned off and the power plug disconnected before cleaning with liquid cleaning 
agents. 

Use only standard cleaning agents for plastic surfaces. 

The unit may only be opened, repaired and serviced by authorised and trained personnel.

 

5.4

 

Interference 

The unit meets EMC regulations for medical products to ensure protection against emission and radiation. 

Special caution should be taken when using this unit in combination with high-frequency devices. 

 

Содержание Sana comfort 150 REHA

Страница 1: ...Article no 2 520064 rev b Seat ergometer Sana comfort 150 250 REHA User Guide...

Страница 2: ...en designed and manufactured in accordance with the relevant requirements of the EC directive 93 42 EEC This declaration loses its validity if the above devices are modified without ergosana s consent...

Страница 3: ...notes 12 5 1 Precautions during operation 12 5 2 Safety precautions when operating with other devices 12 5 3 Maintenance safety precautions 12 5 4 Interference 12 6 Start up and initial preparation 13...

Страница 4: ...pectoris serious hypertonia at rest carditis insufficiency of the heart serious valvular heart defect serious cardiac arrhythmia at rest aortic aneu rysm or other manifest cardiovascular diseases 1 3...

Страница 5: ...essories Every device comes with Power cable with European plug Blood pressure cuff for 250 User guide Inspection report 2 3 Potential equalisation A standard potential equalisation stud is located on...

Страница 6: ...250 Indirectly with a specific modified measuring system based on R R and computer analysis including maximal suppression of artefacts during ergometry Automatic deflation rate of 3 mmHg pulse Meas u...

Страница 7: ...environment and the humidity is at least 30 especially if the floors are synthetic 5 If disorders should nevertheless occur especially in the vicinity of devices labelled with the symbol non ionic el...

Страница 8: ...ust the device so that it is flush with the floor The ergometer is then fully stabilised 3 2 2 Seat adjustment Mechanical seat adjustment The seat is infinitely variable horizontally in order to accur...

Страница 9: ...he complete range of information is located on the front side under a foil key board with a see through window The control elements for the adjustment and operation of the ergome ter are located on th...

Страница 10: ...nt measurement data is shown in the display in alphanumeric and graphic forms It is thus especially easy to monitor exercise testing The cursor can be moved through the selection menu in the display w...

Страница 11: ...ilable for larger arm diameters A microphone is installed in a microphone pocket on the inside of the cuff It serves the transmission of the blood pressure sound The connection cable with an air and a...

Страница 12: ...clamps with the levers positioned vertically downward Secure clamping is en sured when the handles are then again turned to this position during the adjustment procedure after every movement The hold...

Страница 13: ...care fully According to international agreement the blood pressure should be measured on the left arm which is near the heart as the flow impedance level is lowest there An exception to this rule is...

Страница 14: ...metry is highlighted with a black bar This means the item is activated It is possible to select an exercise program directly from here and begin ergometry Beforehand however the five varying exercise...

Страница 15: ...on ok and the window containing the settings menu for ergome try program no 1 appears Check the existing settings for Type of load Stage or Ramp Initial load Increase in load Stage time Blood pressure...

Страница 16: ...ber Initial load watts Increase in load watts Stage time min BP interval min Recovery load watts 1 30 10 1 2 20 2 25 25 2 2 25 3 50 25 2 2 25 4 50 50 3 3 50 5 75 50 3 3 50 The program always returns t...

Страница 17: ...the ergometer via an interface cable For our ergometers this is a type RS 232 interface which is isolated to ensure the patient s safety The appropriate baud rate must be selected in the program Sett...

Страница 18: ...ing a training program on the ergometer To define a training program select the menu option Define program Then select the menu option Train ing using the arrow keys The below settings panel is displa...

Страница 19: ...the training phase It is important that the body heart and circulation are trained but no overload is exerted The pulse steady state program is a very easy means to achieve this If the performance dec...

Страница 20: ...used in combination with a number of rehabilitation systems To be able to implement this upgrade the ergometer has the following additional functions or aggregates a ECG amplifier incl USB converter...

Страница 21: ...bus If several ergometers are in use the data transfer for the rehabilitation control program Sana Sprint remote operation is performed via the USB bus only Please note The RS 232 interface is used fo...

Страница 22: ...th a soft cloth that is dry or moist Commercially available cleaning agents for household appliances can be used The saddle should be cleaned with a leatherette cleaner It is imperative to make sure t...

Страница 23: ...tch After a continuity check change the fuses if necessary Return the fuse switch to the well and press it into the lock in position Replace fuses only with other fuses of the same type with the same...

Страница 24: ...gents are trained in the service of our devices Please contact one of these specialist dealers if your unit requires servicing If this is not possible please contact the company s central service depa...

Страница 25: ......

Отзывы: