21
PUMP TROUBLE SHOOTING
Step 7:
Is there 12 VDC between the #13 relay terminal and #14 relay terminal
in the control box when the trigger is pulled?
YES:
Replace the relay cube.
NO:
Go to step #8.
Step 8:
Is there 12 VDC between the #1 cube timer terminal and #3 cube timer terminal
in the control box when the trigger is pulled?
YES:
Check the wires between the two relay for damage.
NO:
Go to step #9.
Step 9:
Is there 12 VDC between the #2 cube timer terminal and #3 cube timer terminal
in the control box with out the trigger being pulled?
YES:
Replace the cube timer.
NO:
Call Crafco, Inc. and speak to a customer service technician.