3.4.2.2.2 Consumption in transparent mode - option S0502A
Table 11 : Consumption in Low Power mode with option S0502A @ 25 °C without battery charging
Low Power mode
Average I nominal
Unit.
V
IN
6.5
12
24
32
V
GSM / GPRS
55
30
20
15
mA
The GenPro 25e is in Low Power mode with the command
AT+EGLOP=1,xx
.
The GenPro 25e is attached to the network.
Table 12 : Consumption in attached mode with option S0502A @ 25 °C without battery charging
Attached mode
I
MOY MAX.
Unit.
V
IN
6.5
12
24
32
V
GSM / GPRS
70
40
20
15
mA
The GenPro 25e is attached to the network.
Table 13 : Consumption in data transfer with option S0502A @ 25 °C without battery charging
Unit
V
IN
6.5
12
24
32
V
GSM
900
(1)
I
MOY MAX
270
130
70
50
mA
I
Peak MAX
1380
640
320
240
mA
1 800
(2)
I
MOY MAX
190
100
50
40
mA
I
Peak MAX
760
380
190
150
mA
GPRS
1 Rx / 1 Tx
900
(1)
I
MOY MAX
260
130
60
50
mA
I
Peak MAX
1370
630
310
240
mA
1 800
(2)
I
MOY MAX
180
90
50
40
mA
I
Peak MAX
740
370
190
150
mA
3 Rx / 2 Tx
900
(1)
I
MOY MAX
370
180
90
70
mA
I
Peak MAX
1110
540
270
210
mA
1 800
(2)
I
MOY MAX
250
130
70
50
mA
I
Peak MAX
640
330
170
130
mA
(1)
adapted antenna, RF power max. 33dBm.
(2)
adapted antenna, RF power max. 30dBm.
Table 14 : Consumption of the battery charge @ 25 °C
Battery charge
I
MOY MAX.
Unit.
V
IN
7.2
12
24
32
V
180
110
55
40
mA