EG_GenPro25e_1055_UG_002_UK
Page 28 / 58
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modification.
Dct_427_02
3.5.2
Analog input 0
– 10 V (Option S0434B)
Table 17 : Characteristics of the analog input option S0434B
Signal
Connector
Pins number
I/O
Kind of I/O
Description
ANA1
GND
1 Connector 2 pins
3 Connector 4 pins
I
Analog
Analog input 0
– 10 V
Corresponds to wires
Yellow for ANA1
Black
for GND
see ANNEX 1 - 4-pins Micro-FIT cable (Power supply) et
ANNEX - 2-wire Micro FIT cable connector (Input/Output)
Table 18 : Characteristics of the analog input option S0434B
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Analog input
ANA1
-0.3
12
V
DC
Conversion range
6.5 V ≤ +V
DC
≤ 32V
0.010
10.33
V
DC
Polarization current
from 10 mV to 10.33 V
1.34
350
µA
DC
Figure 10 : Internal electrical scheme of the option Analog S0434B
The integrator has the responsibility to protect the input from electric disturbances and to
respect the values of the functioning parameters.