16
Operators Manual ES-650PIA
Operating instructions
Before using your leaf and waste vacuum cleaner, make
sure that
•
the unit is placed on a firm, level surface,
• the collecting bag is hooked in,
• the suction trunk is adjusted to the correct height,
• the fuel tank is full,
• the throttle lever is set to “STOP/MIN”.
Start the machine:
• Set the choke lever to “CLOSE”,
• Set the fuel tap to “ON”,
• Set the stop switch to “ON”,
• Pull the starter rope - engine running -,
• Set the choke lever to “OPEN”,
• Slowly set the throttle lever to “full throttle”.
Warning:
Highly flammable substances (e. g. embers,
hot barbecue coal) can ignite when you hit a
hot surface.
Risk of injury due to light
flammable substances.
Installing the collecting bag
• If you use a dust cover in addition to the dust bag, this
must be put in first. Slide the smaller opening of the
black dust cover over the frame of the rolling bag. Pull
the edge over the upper frame of the rolling bag with
the elastic band. Then insert the bag with the closed
side first into the dust cover and pull the edge over the
upper frame of the rolling bag with an elastic band. Now
you can push the Rolling Bag with collecting bag under
the handle of the leaf and waste vacuum cleaner from
behind and fix it with the quick release fastener.
Empty the collection bag
• Shut down the motor before removing the rolling bag
or collecting bag.
• Push the Rolling Bag upwards and release the locking
lever (note pawl). Lower the rolling bag and pull out of
the leaf vacuum. Remove the bag and empty it or tip
over the rolling bag and pour out the waste or leaves.
The coupling is done in reverse order.
Insert wet collection bag
• Proceed exactly the same way when inserting the wet
collection bag as when installing the leaf sack.
DANGER:
Never operate the leaf and waste suction unit
without a collection bag.
Stop the engine before opening or removing
the bag.
Risk of serious injuries.
Shutting down the machine
• Set the throttle lever to “STOP/MIN,
•
Set the stop switch to “Off”,
• Set fuel tap to “OFF”.
In an Emergency Situation
• Remove drive (ES-620, ES-640PIA),
• Set the stop switch to “OFF”.
Leaf Bag
Rolling Bag
Wet
Collection
Bag
Dust Cover
Содержание ES-650PIA
Страница 23: ...23 Operators Manual ES 650PIA...