Table 3-2: CNF[4:0] Setting for CNF[6] = 1b
CNF[4:0]
Host Bus
00000b
Parallel Direct 80 Type 2: 1 CS#
00001b
Reserved
00010b
Parallel Indirect 80 Type 2
00011b
Reserved
00100b
Parallel Direct 80 Type 1: 1 CS#
00101b
Parallel Direct 68: 1 CS#
00110b
Parallel Indirect 80 Type 1
00111b
Parallel Indirect 68
01000b
Parallel Direct 80 Type 2: 2 CS#
01001b
Reserved
01010b
Reserved
01011b
Reserved
01100b
Parallel Direct 80 Type 1: 2 CS#
01101b
Parallel Direct 68: 2 CS#
01110b
Reserved
01111b
Reserved
10000b
Serial on HVDD1: Data valid on falling edge
10001b
Serial on HVDD2: Data valid on falling edge
10010b
Reserved
10011b
Reserved
10100b
Reserved
10101b
Reserved
10110b
Reserved
10111b
Reserved
11000b
Serial on HVDD1: Data valid on rising edge
11001b
Serial on HVDD2: Data valid on rising edge
11010b
Reserved
11011b
Reserved
11100b
Reserved
11101b
Reserved
11110b
Reserved
11111b
Reserved
= Required settings when using S5U13U00P00C100 USB Adapter board