MASK DATA CHECKER MDC62XX
IX-4
EPSON
S1C62 FAMILY
DEVELOPMENT TOOL REFERENCE MANUAL
4 ERROR MESSAGES
4.1 Data Error
The program data file and option data file and melody data file are checked during packing; the packed
data file is checked during unpacking.
If there are format problems, the following error messages are displayed.
4.1.1
Program data error
4.1.2
Function option data error
* \ sometimes appears as ¥, depending on the personal computer being used.
4.1.3
Segment option data error
4.3 System Error
* \ sometimes appears as ¥, depending on the personal computer being used.
4.2 File Error
1. DIRECTORY FULL.
2. DISK WRITE ERROR.
The directory is full.
Writing on the disk is failed.
Error Message
Explanation
1. <File_name> FILE IS NOT FOUND.
2. PACK FILE NAME (File_name) ERROR.
3. PACKED FILE NAME (File_name) ERROR.
The file is not found or the file number set in CONFIG.SYS
is less than 10.
The packed input format for the file name is wrong.
The unpacked input format for the file name is wrong.
Error Message
Explanation
1. HEX DATA ERROR : NOT COLON.
2. HEX DATA ERROR : DATA LENGTH. (NOT 00-20h)
3. HEX DATA ERROR : ADDRESS.
4. HEX DATA ERROR : RECORD TYPE. (NOT 00)
5. HEX DATA ERROR : DATA. (NOT 00-FFh)
There is no colon.
The data length of 1 line is not in the 00–20H range.
The address is beyond the valid range of the program,
melody and scale ROM.
The record type of 1 line is not 00.
The data is not in the range between 00H and 0FFH.
Error Message
Explanation
There are too many data in 1 line.
The checksum is not correct.
The end mark is not : 00000001FF.
There is duplicate definition of data in the same address.
6. HEX DATA ERROR : TOO MANY DATA IN ONE LINE.
7. HEX DATA ERROR : CHECK SUM.
8. HEX DATA ERROR : END MARK.
9. HEX DATA ERROR : DUPLICATE.
1. OPTION DATA ERROR : START MARK.
2. OPTION DATA ERROR : OPTION NUMBER.
3. OPTION DATA ERROR : SELECT NUMBER.
4. OPTION DATA ERROR : END MARK.
The start mark is not "\OPTION". (during unpacking) *
The option number is not correct.
The option selection number is not correct.
The end mark is not "\\END" (packing) or "\END" (unpacking).*
Error Message
Explanation
1. SEGMENT DATA ERROR : START MARK.
2. SEGMENT DATA ERROR : DATA.
3. SEGMENT DATA ERROR : SEGMENT NUMBER.
4. SEGMENT DATA ERROR : SPEC.
5. SEGMENT DATA ERROR : END MARK.
The start mark is not "\SEGMENT". (during unpacking) *
The segment data is not correct.
The SEG No. is not correct.
The output specification of the SEG terminal is not correct.
The end mark is not "\\END" (packing) or "\END" (unpacking).*
Error Message
Explanation
Содержание S1C62 Family
Страница 1: ...MF599 06 Development Tool Reference Manual CMOS 4 BIT SINGLE CHIP MICROCOMPUTER S1C62 Family ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 20: ......
Страница 22: ......
Страница 26: ......
Страница 28: ......
Страница 30: ......
Страница 54: ......
Страница 56: ......
Страница 58: ......
Страница 70: ......
Страница 72: ......
Страница 74: ......
Страница 82: ......
Страница 84: ......
Страница 86: ......
Страница 98: ......
Страница 100: ......
Страница 112: ......
Страница 164: ...Format ICE CONTROL SOFTWARE ICS62XX VIII 50 EPSON S1C62 FAMILY DEVELOPMENT TOOL REFERENCE MANUAL ...
Страница 198: ...Format ICE CONTROL SOFTWARE ICS62XX VIII 84 EPSON S1C62 FAMILY DEVELOPMENT TOOL REFERENCE MANUAL ...
Страница 199: ...Format ICE CONTROL SOFTWARE ICS62XX S1C62 FAMILY EPSON VIII 85 DEVELOPMENT TOOL REFERENCE MANUAL 3 7 HELP Command ...
Страница 206: ......
Страница 207: ...IX MASK DATA CHECKER MDC62XX This part explains how to operate the MDC62XX Mask Data Checker for the S1C62 Family ...
Страница 208: ......
Страница 210: ......