Maintenance 2. Periodic Inspection
S5 Rev.5
85
2.3.6 Joint #5 Reduction Gear Unit
A
B
A
B
Air Vent (Plug M5)
Grease Inlet (Plug M5)
Name
Quantity
Note
Maintenance
Parts
Grease for reduction gear
5 g
SK-1A
R13ZA00330100
Liquid gasket
Proper quantity
1206C
R13B031201
(1) Remove the plug from the air vent.
Plug: LP-M5
Be sure to remove the plug from the air vent. When grease is being added while
the plug is in the air vent, the internal pressure increases. Increasing internal
pressure may cause malfunction of the robot system.
(2) Remove the plug from the grease inlet.
Plug: LP-M5
(3) Attach a grease nipple to the grease inlet.
(The grease nipple is supplied with the Manipulator.)
Grease nipple: M5
(4) Pump grease into the reduction gear unit from the grease inlet using a grease gun.
Grease
: Grease for reduction gear (SK-1A)
Quantity : 5 g
(5) Operate the Manipulator at low power mode speed for one hour to run-in the grease.
(6) Wipe off excess grease exhausted from the air vent with wiping cloth.
(7) Attach the plug to the air vent.
Plug: LP-M5 (Apply liquid gasket.)
(8) Remove the grease nipple from the grease inlet.
Grease nipple: M5
(9) Attach the bolt to the grease inlet.
Plug: LP-M5 (Apply liquid gasket.)
NOTE
Содержание ProSix S5 Series
Страница 1: ...Rev 5 EM133R2483F EPSON ProSix S5 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual S5 series Rev 5 ...
Страница 10: ...viii S5 Rev 5 ...
Страница 16: ......
Страница 84: ...Setup Operation 5 Motion Range 70 S5 Rev 5 ...
Страница 85: ...71 Maintenance This volume contains maintenance procedures with safety precautions for Manipulators ...
Страница 86: ...S5 Rev 5 72 ...