Maintenance 5. Joint #2 (Replacing the Motor)
S5 Rev.5
111
CAUTION
■ Wear protective gear including a mask, protective goggles, and oil-resistant
gloves during grease up. If grease gets into your eyes, mouth, or on your skin,
follow the instructions below.
If grease gets into your eyes : Flush them thoroughly with clean water, and
then see a doctor immediately.
If grease gets into your mouth : If swallowed, do not induce vomiting. See a
doctor immediately.
If grease just gets into your mouth, wash out
your mouth with water thoroughly.
If grease gets on your skin
: Wash the area thoroughly with soap and
water.
- After parts have been replaced (motors, reduction gear units, timing belts, etc.), the
Manipulator cannot perform positioning properly because a mismatch exists between the
origin stored in each motor encoder and its corresponding origin stored in the Controller.
After replacing the parts, it is necessary to match these origins.
The process of aligning the two origins is called “Calibration”.
Refer to
Maintenance 12. Calibration
and follow the steps that pertain to the software
you are using to perform the calibration.
Joint #2 Motor
WARNING
■
Always use at least two people when removing the motor unit. Remove the
motor unit while one person is supporting the upper structure (Arms #2 to #6).
The upper structure folds inward at Joint #2 as soon as the motor unit is removed
and the brake is released. Failure to properly support the upper structure may
result in serious bodily injury and/or severe equipment damage.
NOTE
Содержание ProSix S5 Series
Страница 1: ...Rev 5 EM133R2483F EPSON ProSix S5 series MANIPULATOR MANUAL ...
Страница 2: ...Manipulator manual S5 series Rev 5 ...
Страница 10: ...viii S5 Rev 5 ...
Страница 16: ......
Страница 84: ...Setup Operation 5 Motion Range 70 S5 Rev 5 ...
Страница 85: ...71 Maintenance This volume contains maintenance procedures with safety precautions for Manipulators ...
Страница 86: ...S5 Rev 5 72 ...