2. Description
12
Part Feeding 7.0 IF-240 Rev.5
2.4.2 Power connection
WARNING
-
Before supplying power to the part feeder, check that the
distribution voltage is the same as the nominal voltage.
-
Never disconnect the power cables when the unit is on.
Always turn the machine off and then cut the power.
-
Use PELV (protected extra-low voltage) nominal voltage.
-
Unplug the main power plug when plugging / unplugging
the cord.
Figure 2-7: Power connection
Pin
Signal description
(1)
24VDC PELV S-Power
(2)
0V GND S-Power
(3)
24VDC PELV Power
(4)
0V GND Power
(5)
EARTH
Connector type (on IF-240 side): M16, 5 Poles, male
In case of all functions working simultaneously (vibration, backlight, outputs), the current
increases to 8A.
Characteristic
Value
Voltage
+24VDC ±5%
Current Power
5A
Current S-Power
3A
S-Power is the safety power for the backlight.
Cutting this S-Power ensures that the backlight stays OFF.
(e.g. to secure IR backlight danger).
NOTE
Содержание Part Feeding 7.0
Страница 1: ...Rev 5 EM208S4401F EPSON RC 7 0 Option Part Feeding 7 0 IF 240 ...
Страница 2: ...EPSON RC 7 0 Option Part Feeding 7 0 IF 240 Rev 5 ...
Страница 6: ...iv Part Feeding 7 0 IF 240 Rev 5 ...
Страница 9: ...Hardware IF 240 ...
Страница 10: ......
Страница 26: ...2 Description 18 Part Feeding 7 0 IF 240 Rev 5 Mechanical interfaces of the platform ...
Страница 42: ...4 Maintenance and component replacement 34 Part Feeding 7 0 IF 240 Rev 5 ...