EPL-N2700 Optional Units
Revision A
Operating principles
LCC Unit Unit
181
6.3.2.7 Paper Size Regulating Plate
The Regulating Plate (vertical) is screwed into position (not used for
Letter crosswise). The Regulating Plate (horizontal) can be slid into any
desired position.
Whenever the positions of the Paper Size Regulating Plates have been
changed, be sure to perform the paper size setting procedure. (See
Figure 6-35.)
Figure 6-35. Paper Size Regulating Plates
6.3.2.8 Paper Size Setting
The paper sizes that can be set are A4 LEF and Letter LEF. After the
positions of Paper Size Regulating Plate have been changed, set the
dip switch on the control board according to the current paper size.
Figure 6-36. Paper Size Setting
Table 6-2. Paper Size setting
Vertical Paper Size Regulating Plate
Horizontal Paper Size Regulating Plate
SW No.
Letter Crosswise
A4 Crosswise
1
OFF
ON
2
OFF
OFF
3
OFF
OFF
4
OFF
OFF
PWB-A
SW1
ON
Off
1 2 3 4