11. Calibration
Part 2: Maintenance
180
11.1 Calibration for EPSON RC+ Controller
Refer to the EPSON RC+ on-line help for details of commands used in this section.
During the following steps, you may have to open the safeguard to gain access to the
manipulator, depending on the system setup. With the safeguard open, the manipulator
motors will turn OFF unless attend mode is ON. When executing Monitor Window
commands, attend mode must be OFF.
Common procedure for calibration
For both the ES and EL series manipulators, calibration steps (1) to (10) are the same for all
four joints.
(1) Turn ON the power of the RC520 Drive Unit and RC520 PC Control Unit after
moving all joints to within motion range. Check if an error occurs. If an error does
not occur, proceed to next step.
Error F-5001 occurs when the capacitor in the motor encoder is insufficiently charged
because, for example, the motor is new. To change the capacitor, leave the power ON
for 3 or more minutes.
(2) Manually move joints to be calibrated into approximately the 0 pulse position.
Joint #1 : 0 pulse position : aligned with X-axis in robot coordinate system
(See figure below).
Joint #2 : 0 pulse position : parallel with Arm #1 (i.e., straight) regardless of Joint
#1 direction.
Joint #3 : 0 pulse position : uppermost position in working area.
Joint #4 : 0 pulse position : flat surface on the shaft facing in the top of Arm #2
direction.
(Rear)
RC+
)
NOTE
Содержание EL Series
Страница 1: ...ES EL series Rev 9 EM019R893F SCARA ROBOT MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL ES EL series Rev 9 ...
Страница 12: ...x ...
Страница 14: ...2 ...
Страница 16: ...1 Manipulator Part Names Part 1 Setup Operation 4 ...
Страница 30: ...4 User Wires and Pneumatic Tubes Part 1 Setup Operation 18 ...
Страница 42: ...5 End Effectors Part 1 Setup Operation 30 ...
Страница 44: ...6 Attaching a Camera Valve and Other Devices Part 1 Setup Operation 32 ...
Страница 68: ...8 Motion Range and Robot Coordinates Part 1 Setup Operation 56 ...
Страница 70: ...9 Emergency Stop Part 1 Setup Operation 58 ...
Страница 80: ...11 Clean Model Part 1 Setup Operation 68 ...
Страница 92: ...80 ...
Страница 94: ...Maintenance Safety Precautions Part 2 Maintenance 82 ...
Страница 104: ...2 Opening the Covers Part 2 Maintenance 92 ...
Страница 112: ...3 Replacing the Cable Unit Part 2 Maintenance 100 ...
Страница 138: ...5 Replacing the Motors Part 2 Maintenance 126 ...
Страница 162: ...6 Replacing the Reduction Gear Units Part 2 Maintenance 150 ...
Страница 186: ...9 Replacing the Ball Screw Spline Unit Part 2 Maintenance 174 ...
Страница 210: ...11 Calibration Part 2 Maintenance 198 ...
Страница 214: ...12 Clean Model Maintenance Part 2 Maintenance 202 ...
Страница 224: ...13 Protected Model Maintenance Part 2 Maintenance 212 13 6 Wiring Schematic 2 ...
Страница 236: ...14 Maintenance Part Lists Part 2 Maintenance 224 ...