EPSON AcuLaser C2000 / AcuLaser C1000
Revision E
Troubleshooting
Image Quality Troubleshooting
137
White and
Black smear
Paper is wet.
1
Use paper after kept in the room
for a while.
White smear
2
Replace the fusing unit.
If it occurs only for the
optional duplex paper
feed.
3
Replace the optional duplex unit.
Horizontal line
1-2 mm pitch
-
Replace the print head.
35mm develop pitch
irregularity
-
Replace the color toner
cartridge.
75mm transfer roller
Replace the transfer roller unit.
95mm OPC drum
-
Replace the OPC drum.
204mm fusing belt
-
Replace the fusing unit.
Rear end 35mm
Replace the fusing unit.
Line and point that
occurs at the regular
page.
Replace the belt unit.
Table 3-10. Image Quality Troubleshooting (continued)
Abnormal
Image
Cause
Step
Solution
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Содержание ACULASER COLOR 1000
Страница 1: ...EPSON ACULASERCOLOR2000 ACULASERCOLOR1000 A4 Color Laser Printer SEPG00004 SERVICE MANUAL ...
Страница 12: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Страница 68: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 104: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 138: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 181: ...EPSON AcuLaser C2000 AcuLaser C1000 Revision E Disassembly and Assembly Program ROM Update AcuLaser C2000 181 ...
Страница 182: ...C H A P T E R 5 ADJUSTMENT ...
Страница 187: ...C H A P T E R 6 MAINTENANCE ...
Страница 189: ...C H A P T E R 7 APPENDIX ...
Страница 191: ......
Страница 192: ......
Страница 220: ......
Страница 221: ......
Страница 222: ......
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......