5. Remove the PH Unit (Black) according to the following procedure.
1. Move the front side of the PH Unit to left a little, and remove the Boss [9] from the locating
hole [10].
2. Lift up the front side of the PH Unit a little.
3. Remove the Boss [11] at the rear side of the PH Unit from the locating hole [12].
4. Remove the PH Unit [14].
6. Follow the same procedures to remove all PH Units.
C H E C K
P O I N T
Since the back of the PH Unit is pushed to the right with the two Plate Springs [13],
remove it by tilting the backside of the PH Unit to the left as shown in the figure
above.
[14]
4037F2C111DB
[11]
[13]
[12]
4038F2C110DA
[9]
[10]
<Assembling procedure of the PH Unit>
1. Fit the back of the PH Unit [1] to the Plate Spring [2] of installation plate.
2. Push the PH Unit [3] along the right side line of PH Unit installation plate all the way and fit
it into the Plate Spring [4].
3. Make sure that the two Bosses [5] at front and rear side of the PH Unit fit in the locating
hole [6].
4037F2C113DB
[1]
[2]
4037F2C114DA
[3]
[5]
[6]
[5]
[6]
[4]
Содержание Aculaser C9200N
Страница 1: ...SERVICE MANUAL A3 Color Laser Printer EPSONAcuLaser C9200N SEPG08001 Confidential ...
Страница 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 31: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 96: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 156: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 313: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 331: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 337: ...Confidential C H A P T E R 7 APPENDIX ...
Страница 362: ...EPSON AcuLaser C9200N Revision D APPENDIX Information Sheet 362 Confidential Figure 7 5 Maintenance Status Sheet ...