E406
Abnormally low toner density detected Black TCR Sensor
Mixture ratio of the toner and carrier in the developing machine is lower than the specified value.
p.117
E407
Abnormally high toner density detected Black TCR Sensor
Mixture ratio of the toner and carrier in the developing machine is higher than the specified value.
p.117
E500
Main Motor's failure to turn
The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is
turning.
p.118
E501
Main Motor turning at abnormal timing
The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains
stationary.
p.118
E510
Color PC Drum Motor's failure to turn
The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is
turning.
p.118
E511
Color PC Drum Motor's turning at abnormal timing
The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains
stationary.
p.119
E520
Color Developing Motor's failure to turn
The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is
turning.
p.119
E521
Color Developing Motor's turning at abnormal timing
The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains
stationary.
p.120
E550
Suction Fan Motor's failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.120
E551
Cooling Fan Motor/1's failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.120
E552
Fusing Cooling Fan Motor/1's
failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.120
E553
Fusing Cooling Fan Motor/2's
failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.121
E554
Ozone Ventilation Fan Motor's failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.121
E555
Power Supply Cooling Fan Motor/1's failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.121
E556
Cooling Fan Motor 2's failure to turn
The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains
stationary.
p.121
E600
Cyan TCR Sensor adjustment failure
TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
p.122
E601
Magenta TCR Sensor adjustment failure
E602
Yellow TCR Sensor adjustment failure
E603
Black TCR Sensor adjustment failure
p.122
E610
1st Image Transfer ATVC (color) failure
An abnormal average value is detected while performing the first image transfer ATVC of color.
p.123
Table 3-16. Error Code List
Code
Item
Detection Timing
Reference
Содержание Aculaser C9200N
Страница 1: ...SERVICE MANUAL A3 Color Laser Printer EPSONAcuLaser C9200N SEPG08001 Confidential ...
Страница 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 31: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 96: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 156: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 313: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 331: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 337: ...Confidential C H A P T E R 7 APPENDIX ...
Страница 362: ...EPSON AcuLaser C9200N Revision D APPENDIX Information Sheet 362 Confidential Figure 7 5 Maintenance Status Sheet ...