EPSON AcuLaser C9200N
Revision D
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
189
Confidential
2. Remove the Flat Cable [4] and the Connector [5] of the PH Unit (Black).
3. Remove the Claw [6] and remove the Gear [7] of the PH Unit (Black).
[7]
[6]
4038F2C108DB
[4]
[5]
4038F2C107DA
When removing the Stopper, use care so that both ends of the Stopper will not open
but stay parallel as shown in the figure above. Keep using the Stopper after once
stretched out may cause uneven pitch or other image troubles.
4. Remove the Stopper [8] of the PH Unit (Black).
[8]
4038F2C109DA
○
×