Item

 Description of items displayed on the screen

BLMOD 

CALBN 

CALOK 

CANCEL 

FAIL 

OUTRG 

PMODE 

POWTIME 

RESET 

SS CK 

SS OK 

SSERR 

SETUP 

TARE 

TR ER 

UNTARE 

UNIT 

ZERO 

ZR ER 

Backlight mode setting

Calibration

Calibration OK

Cancel parameter setting

Plant calibration failed

Out of range

Plant calibration mode

Auto power-off time setting

Factory reset

Sensor check

Sensor OK

Sensor error

Parameter setting

Tare removal

Tare removal error

Untare

Unit setting

Zero

Zero error

Troubleshooting

1

.

System halt

This product has received strict testing before delivery and no system halt will occur under 
normal conditions. Please remove the battery, and refit it again to recover its normal operation
in case of system halt.

2

.

Start-up failure

2

.

1Turn off the power supply. Disassemble the gauge outfit, and use a voltmeter to measure 

battery voltage; if the voltage is below 3.5V, it means that battery voltage is extremely low, 
which may result in start-up failure; replace the old battery with new one in this case.

2

.

2Disassemble the gauge outfit, and use a voltmeter to measure battery voltage; if the 

voltage is over 3.5V, just check if the red-black connecting line between battery module and 
instrument panel is disconnected.

2

.

3Other problems. Please contact professionals for testing of panel if power supply is normal.

3

.

Abnormal display

3.1If the sensor is proved to be normal through test, just press the unit switching key to see if 
the data displayed is normal.

3.2Sensor connection: If display of instrument reading is abnormal, just turn off the instrument 
and turn on it again to check screen display; if “SSERR” is displayed on the screen following 
display of “SS CK”, it means that connection of sensor is abnormal; in this case, it is necessary 
to check if connection between the sensor and instrument panel is normal before contacting 
professionals to check if sensor output is normal.

3.3Calibration: If abnormal data is still displayed by the instrument following unit switching, 
just use “unit switching” and “tare removal” in combination to enter the parameter setting mode, 
and recalibrate at the final setting option (for details, please refer to page 10).

4

.

Truck failure

The forks cannot 

be lifted to max. 

height

The hydraulic oil is 

insufficient

The hydraulic oil has 

impurities

Adjusting nut(2-4) or 

adjusting screw(2-6) in 

wrong positions

Air enters  into the cylinder

Seals damaged

1

2

Fault

Possible cause

Action

No.

Appendix

Description

E20V Series Scale Pallet Trucks

The forks cannot 

be lifted

The hydraulic oil is 

insufficient

Add the hydraulic oil

Add the hydraulic oil

Change hydraulic oil

Adjust nut(2-4) or adjusting 

screw(2-6)

Put the finger grip handle in 

the upper position and press 

the handle dozens of times

Replace the damaged seals 

with new seals

Содержание E20V

Страница 1: ...E20V Operating Instructions Scale Pallet Truck Hotline 400 626 9090 Tel 86 573 8622 9999 Fax 86 573 8622 2900 info eoslift com ...

Страница 2: ...efully and retain them properly for future reference The operator needs to have proficient operation skills The operator has responsibility to carefully understand the performance and safety rules of the pallet truck If you have any doubts during the application please don t hesitate to contact Eoslift E20V Series Scale Pallet Trucks ...

Страница 3: ... 02 Ⅲ Installation of handles 03 Ⅳ Adjusting the finger grip handle 04 Table of contents Ⅵ Appendix 13 Ⅶ Troubleshooting 14 Ⅸ Parts list 17 Ⅴ Operating instruction 05 Ⅷ Transport loading test run and storage 16 E20V Series Scale Pallet Trucks ...

Страница 4: ... not operate the pallet truck unless you are fully familiar with it and have been authorized to do so Do not operate the pallet truck unless you have carefully checked its condition Pay special attention to the wheels the handle assemblies the truck frame the unloading plate etc To pull the truck always move the finger grip control handle into the middle position This makes the handle easier to mo...

Страница 5: ...steps If the forks elevate while pumping in the Middle position turn the adjusting nut 2 4 on the adjusting bolt 2 3 or screw 2 6 clockwise until pumping action does not raise the forks and the finger grip control handle works properly Middle position 1 1 Upper Middle Lower 2 3 2 4 2 6 E20V Series Scale Pallet Trucks If the forks descend while pumping in the Middle position turn the screw 2 6 or n...

Страница 6: ...2 1Operating panel Figure 2 1 Operating panel in Normal Weighing Mode Weight display Unit of measurement Battery level Zero On Off back light Unit switching Backlight cursor Dynamic cursor Tare cursor Net weight cursor Zero cursor 1 2 3 4 5 6 7 8 9 10 1 1 Note Abbreviations for the following keys Zero key 0 key Tare removal key T key Unit switch key U key ON OFF key P key TARE E20V Series Scale Pa...

Страница 7: ...ds under ON status is to be displayed on the screen before power off press the key for a while to turn on the back light in the back light mode Press the key for a while for start u Combination key function U key 0 key Factory reset U key T key enter the parameter setting mode 3 Parameter setting mode 3 1Operating panel Figure 3 1 Operating panel in parameter setting mode 1 Input value Calibration...

Страница 8: ...ght mode setting is confirmed press 0 keyfor cyclic switching of items displayed on the screen BL ON and BL OFF refer to Back Light On and Off respectively press T key to confirm setting and proceed with next setting 3 4Auto Power off Time Setting Default auto power off time of the system is 5 minutes when cargoes remain unchanged Proceed with auto power off time setting once back light mode setti...

Страница 9: ...g icon as displayed is blank or data displayed is indistinct It is better not to put the instrument into prolonged outdoor operation in case of rain and snow prolonged exposure of instrument to the sunshine is strictly prohibited It is applicable to clean the instrument shell with soft and clean cloth in combination with routine washing solvent never use industrial solvent for cleaning or directly...

Страница 10: ...f panel if power supply is normal 3 Abnormal display 3 1If the sensor is proved to be normal through test just press the unit switching key to see if the data displayed is normal 3 2Sensor connection If display of instrument reading is abnormal just turn off the instrument and turn on it again to check screen display if SSERR is displayed on the screen following display of SS CK it means that conn...

Страница 11: ...truck shall be commissioned according to the following function tests steering traveling braking and combined functions with rated capacity When a truck is inoperative the cargoes if applicable shall be removed with proper tools the truck shall be transported out of the working zone with a proper way When the truck will be shut down and in storage for a long time the storage environment shall be k...

Страница 12: ...93 1 Circlip for hole 25 blackening Nylon wheel φ180 50 white Big wheel shaft galvanized GB894 1 Circlip for shaft 20 blackening Big wheel cover black Big wheel cover white Connecting shaft galvanized Handle black Iron cable clip R type cable clip6 5 GB95 Plain washer 5 galvanized GB95 Plain washer 5 galvanized Washer 53 31 8 3 5 WC02000020 WE07000003 WC02000015 WC02000012 WC02000014 WC02000190 WE...

Страница 13: ...zed Connecting rod assembly black GB893 1 Circlip for hole 25 blackening Sliding bearing 29 25 25 Sliding bearing 18 16 15 Long shaft Bolt pin galvanized Nylon wheel φ180 50 white Big wheel cover black Big wheel cover white Big wheel shaft galvanized GB894 1 Circlip for shaft 20 blackening Washer galvanized Small wheel carrier black E20V Series Scale Pallet Trucks GB818 Pan head screw with cross r...

Страница 14: ...02000004 WC02000075 WC02000218 WC02000003 WC02000027 WC02000026 WC02000847 WE05000004 WC02000074 WC02000118 WE03000009 WC02000160 WC02000120 WC02000007 WC02000011 WE06000001 WC02000075 WC02000022 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 2 1 1 3 2 2 2 2 2 10 2 1 4 1 1 1 1 4 6 2 2 2 2 2 2 4 4 GB879 1 Spring type straight pin 5 26 blackening GB879 1 Spring type...

Страница 15: ... sealing gasket 10 Screw Seal ring UHS35 GB3452 1 O ringφ34 5 3 55 Dustproof ring DH35 Piston rod Safety valve spool Pressure adjusting spring Pressure adjusting screw GB3452 1 O ring φ11 2 2 65 Screw plug Copper gasket Pump body Seal ring UHS18 Dustproof ring DH18 Spring cover Pump core Pressure spring Pin Unloading plate galvanized Integrated valve assembly 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ...

Страница 16: ...φ15 2 2 4 GB3452 1 O ringφ8 1 8 Return valve sleeve GB3452 1 O ringφ9 5 1 8 Stem Unloading spring O ring retainer Ⅱ GB308 Steel ball S7 Liquid inlet valve sleeve GB117 Copper taper pin 2 5 O ring retainerI GB3452 1 O ringφ13 2 2 4 Spring leaf Boost valve spool Spool spring Blind nut GB3452 1 O ring φ21 2 2 65 1 1 2 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 E20V Series Scale Pallet Trucks GB818 Pan head scre...

Страница 17: ...00017 WJ10800009 WJ10800010 Handle welded Clamping roller Roller pin Finger grip handle Spring type pin 5 Spring type pin 6 Spring type pin 7 Locking nut Spring type pin 9 Positioning plate Connecting sheet of pull rod Pull rod Chain Adjusting bolt Spring type pin 15 Bushing Torsion spring Plastic roller 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E20V Series Scale Pallet Trucks Qty NO Parts number Descri...

Отзывы: