background image

7

EN

Please verify upon delivery that all components 

included in the standard scope of delivery are 

available. Missing parts shall be reported to your 

local dealer (supplier).

Standard delivery includes:

• 

1 sauna heater

• 

1 wall-mounting bracket

• 

1 accessory pack with 

1 cable gland PG16 

3 self-tapping screws B 4.2 X 9.5 

4 mounting screws (spax screws)

• 

1 set of sauna stones

• 

Installation and operation guide

Scope of delivery 

Technical Specifications

Nominal voltage

400 V 3 N 50 Hz AC
(connection to 230V 1N AC power supply possible*)

Power rating

4.5 kW

6.0 kW

7.5 kW

9.0 kW

For sauna size

6 - 8 m³

6 - 8 m³

7 - 10 m³

9 - 14 m³

Min. size air inlet and 

exhaust vent

35 x 3 cm

35 x 4 cm

35 x 5 cm

35 x 6 cm

Height

580 mm (755 mm with obligatory 180 mm floor gap)

Width

375 mm

Depth

380 mm

Stone volume

Up to 15 kg sauna stones

Power extension (LSG) Not required

Suitable control units

Econ D series, Emotec / EmoStyle D series, EmoTouch

Leakage current

max. 0,75 mA per kW heating power

Intended use

Sauna heater for use in residential (domestic) saunas

* Connection to 230V 1N AC only in combination with the compatible sauna control unit. Make sure to observe 

the deviating special connection scheme.

Содержание THERMAT

Страница 1: ...INNOVATIVE SAUNA TECH NOLOGY MADE IN GERMANY IP x4 THERMAT Sauna Heater print no 2934 4632 34 18 Installation and operation instruction EN...

Страница 2: ...clearances 8 Mechanical installation and connections 8 9 Inner wiring 10 Connection example 400V 3N 10 Connection example 230V 1N 4 5 6 kW 11 Connection example 230V 1N 7 5 9 kW 12 Special advice for...

Страница 3: ...shipped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Ple...

Страница 4: ...in untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent open ings in each sauna cabin The air int...

Страница 5: ...e cabin size in rela tion to the power input in kW When installing the sauna heater please ensure that the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained P...

Страница 6: ...where the cable exits the sauna heater and guide this cable outside through the hole to the control unit The cable and all other connecting cables mains power cables and cabin lighting should be inst...

Страница 7: ...on to 230V 1N AC power supply possible Power rating 4 5 kW 6 0 kW 7 5 kW 9 0 kW For sauna size 6 8 m 6 8 m 7 10 m 9 14 m Min size air inlet and exhaust vent 35 x 3 cm 35 x 4 cm 35 x 5 cm 35 x 6 cm Hei...

Страница 8: ...g bracket over the air intake vent as shown in the Illust 2 3 and screw it onto cabin wall with the spax screws from the delivery scope Illust 2 Illust 3 Wall mounting bracket 64 cm 58 5 cm cabin wall...

Страница 9: ...ver with spacer Illust 4 Terminal block Lock nut Cable gland Illust 5 3 Close the terminal box with cover using 2 fixation screws Observe that the integrated spacer faces outwards See Illust 4 for det...

Страница 10: ...Hz 400 V 3 x 16 35 x 3 cm 5 x 2 5 mm 5 x 1 5 mm no Econ D series Emotec D series EmoStyle D series EmoTouch 6 0 kW 35 x 4 cm 7 5 kW 35 x 5 cm 9 0 kW 35 x 6 cm All cross sections of a line are minimum...

Страница 11: ...se a proper fuse protection andsuitableconnectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting ca...

Страница 12: ...nectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting cable mains control unit in mm Connecting ca...

Страница 13: ...sauna control unit Risk of fire and damages to control unit and heater Do not just bridge the power input terminals L1 L2 L3 Mare sure to protect each input with an individual fuse Risk of fire and d...

Страница 14: ...daily commercial use we recommend to check the condition of sauna stones every 2 3 months and to reshuffle them By home use the sauna stones need to be checked and reshuffled at least once per year N...

Страница 15: ...other electrical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the sur...

Страница 16: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Страница 17: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...