background image

14

EN

 

Please be sure to note!

Do not insert sauna rocks too tightly in 
the rock store. Place them loose, leaving 
as many spaces as possible to allow the 
free flow of hot air for circulation purpos-

es. •  Please make sure that the stones do 

not put any pressure on the heating ele-
ments.
Remove stones from the sauna heater 
only when they cooled down.
It cannot be excluded that hot rocks or 
their parts fall out of the rock store.

Risk of fire!

Sauna stones are a natural product. Check the 

sauna stones at regular intervals. Aggressive 

sauna essences can weaken the sauna stones 

and cause them to break apart over time. Con-

sult your sauna supplier if necessary. 

Wash the delivered stones with flowing water 

thoroughly and put them into the 

stone bas-

ket 

in a way that they do not put any pressure 

on the heating elements and that the air can 

still circulate through the stones.

The quantity of stones is sufficient to create a 

steam shock, vaporizing about 10 cl of water 

per m³ cabin volume. Always wait at least 10 

minutes after an infusion before repeating it. 

Only then the sauna stones will re-heat suffi-

ciently again.

By daily commercial use we recommend to 

check the condition of sauna stones every 2-3 

months and to reshuffle them.

By home use the sauna stones need to be 

checked and reshuffled at least once per year.

 Never add more essences or vola-

tile oils than advised on the packaging.  
Never use alcohol or undiluted concen-
trates. Caution! Fire hazard!

The sauna heating unit is made of low-corro-

sion material. To enjoy your sauna heating unit 

for a long time you should ensure maintenance 

and take due care about the heater. Always 

make sure that the air supply vents and reflec-

tion surfaces in the area of air intake are free. 

These can easily become clogged with fuzz and 

dust when drawing in fresh air. This reduces the 

air convection in the sauna heating unit and 

can be a cause of too high temperatures.

Clean or de-scale the heater when needed.  

Refer to your sauna supplier or directly to the 

manufacturer in case of defects or signs of wear 

and tear.

Only use original manufacturer‘s replacement 

parts, which can be obtained from your suppli-

er or directly from the manufacturer. 

If you did not use your sauna for a long peri-

od of time, always check before next use that 

cloths, cleansers or other objects have not 

been left on the sauna heating unit or the va-

porizer before turning them on. 

Sauna rocks

Maintenance and care

Содержание THERMAT

Страница 1: ...INNOVATIVE SAUNA TECH NOLOGY MADE IN GERMANY IP x4 THERMAT Sauna Heater print no 2934 4632 34 18 Installation and operation instruction EN...

Страница 2: ...clearances 8 Mechanical installation and connections 8 9 Inner wiring 10 Connection example 400V 3N 10 Connection example 230V 1N 4 5 6 kW 11 Connection example 230V 1N 7 5 9 kW 12 Special advice for...

Страница 3: ...shipped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Ple...

Страница 4: ...in untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent open ings in each sauna cabin The air int...

Страница 5: ...e cabin size in rela tion to the power input in kW When installing the sauna heater please ensure that the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained P...

Страница 6: ...where the cable exits the sauna heater and guide this cable outside through the hole to the control unit The cable and all other connecting cables mains power cables and cabin lighting should be inst...

Страница 7: ...on to 230V 1N AC power supply possible Power rating 4 5 kW 6 0 kW 7 5 kW 9 0 kW For sauna size 6 8 m 6 8 m 7 10 m 9 14 m Min size air inlet and exhaust vent 35 x 3 cm 35 x 4 cm 35 x 5 cm 35 x 6 cm Hei...

Страница 8: ...g bracket over the air intake vent as shown in the Illust 2 3 and screw it onto cabin wall with the spax screws from the delivery scope Illust 2 Illust 3 Wall mounting bracket 64 cm 58 5 cm cabin wall...

Страница 9: ...ver with spacer Illust 4 Terminal block Lock nut Cable gland Illust 5 3 Close the terminal box with cover using 2 fixation screws Observe that the integrated spacer faces outwards See Illust 4 for det...

Страница 10: ...Hz 400 V 3 x 16 35 x 3 cm 5 x 2 5 mm 5 x 1 5 mm no Econ D series Emotec D series EmoStyle D series EmoTouch 6 0 kW 35 x 4 cm 7 5 kW 35 x 5 cm 9 0 kW 35 x 6 cm All cross sections of a line are minimum...

Страница 11: ...se a proper fuse protection andsuitableconnectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting ca...

Страница 12: ...nectioncable Riskoffireanddamagestohardwarebyimproperconnection Power rating per DIN Electrical connection Fuse protection for control unit in A Connecting cable mains control unit in mm Connecting ca...

Страница 13: ...sauna control unit Risk of fire and damages to control unit and heater Do not just bridge the power input terminals L1 L2 L3 Mare sure to protect each input with an individual fuse Risk of fire and d...

Страница 14: ...daily commercial use we recommend to check the condition of sauna stones every 2 3 months and to reshuffle them By home use the sauna stones need to be checked and reshuffled at least once per year N...

Страница 15: ...other electrical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the sur...

Страница 16: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Страница 17: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Отзывы: