10
EN
L1 L2 L3 N
Sensor
Limiter
S1
Saunasteuergerät
control unit
U V W WB WM N
400 V AC 3N
N U V W
max. 9 kW
Sensor
Connection example for 400V 3N AC
!
Caution!
Make sure to connect the neutral wire N.
Power
acc. DIN
Electrical
connection
Fuse control
unit in A
Minimum dimensions
of air intake and
exhaust vents
Connecting cable
main - control
unit in mm²
Connecting cable
control unit -
heater in mm²
Power extension
(LSG) needed
For operation with control units
4,5 kW
3N AC
50 Hz
400 V
3 x 16
35 x 3 cm
5 x 2,5 mm²
5 x 1,5 mm²
no
Econ D-series
Emotec D-series
EmoStyle D-series
EmoTouch
6,0 kW
35 x 4 cm
7,5 kW
35 x 5 cm
9,0 kW
35 x 6 cm
All cross sections of a line are minimum diameters in mm² (Copper line). All cross sections are given solely for 400V 3N power supply!
1500 W
1500 W
1500 W
3x G-Ltg
4,5 kW
U V W
N
PE
N N
X Y Z
1500 W
1500 W
1500 W
3x G-Ltg
6,0 kW
U V W
N
PE
N N
X Y Z
1500 W
1500 W
1500 W
1500 W
3x G-Ltg
7,5 kW
U V W
N
PE
N N
X Y Z
1500 W
1500 W
1500 W
1500 W
1500 W
3x Q-Ltg
9,0 kW
U V W
N
PE
N N
X Y Z
1500 W
1500 W
1500 W
Inner wiring and heating elements
Specifications for default connection 400V 3N AC
Default connection