12
EN
Commissioning
Turn the timer knob to start the sauna heater.
When switched on to the max., the unit runs for
4 hours before automatically switching off.
The operating status 'ON' is indicated via a green
lamp.
If the stove is heating up, the red lamp also shines.
Once the heating time of 4 hours has expired, the
two lamps (red and green) go off.
To switch off the device, the clock needs to be set
to '0' again. Both lamps are now off.
1/2
1/2
1/2
2
3
1/2
1
4
0
Thermostat
Timer
Please note that the sauna needs about 45 mi-
nutes to heat up and create the typical sauna
climate.
Use the thermostat knob to pre-select the tem-
perature in a range of approx. 40 °C to 100 °C.
Please also note that the sensors only record
the temperature around them. It is therefore
possible that the temperature in other parts of
the cabin may vary, however this is typical in a
sauna.
Please note that the temperature sensor is in-
side the unit; an external stove sensor is not
necessary. The design of the cabin can impact
on the way the cabin heats up and cause tem-
perature differences of up to 15°C.
Also, many bimetal thermometers (wall-moun-
ted) react sluggishly, so that the real tempera-
ture is only shown after about an hour in some
cases. If possible, the thermometer should not
be mounted with its entire casing on the cabin
wall, but a slight gap should be left. This redu-
ces the reaction time.
It is also possible that your thermometer shows
a lower value than you set on the control unit.
Remark
Is the bathing temperature not reached or does
the temperature on the thermometer vary from
that in the cabin?
red
green
Safety cut-out
The sauna heater is equipped with a safety
temperature limiter (STB). If there is a malfunc-
tion, this STB switches off all 3 phases for rea-
sons of safety.
If the STB triggers, it needs to be reset mecha-
nically.
Now press the locking pin below the cover by
pressing it with a screwdriver through the 7th
ventilation slit in the first row of holes until you
feel the switch point.
If the STB triggers again after commissioning,
the device needs to be checked by a qualified
technician.