Montage

The sauna cabin interior must be at least 1.90 

m in height.
Maintain at least 100 cm clearance between the 

upper edge of the heater and the cabin ceiling

Der Abstand zwischen Ofenschutz und Kabi-

nenwand oder anderen brennbaren Materialien 

muss mindestens 4 cm betragen.
Der Ofenschutz ist nicht im Lieferumfang en-

thalten.

Minimum distances

Abb. 1

1. In compliance with Fig. 2, screw 4 attach-

ment screws above the air intake opening 

into the cabin wall so that there is approx. 3 

mm space between the wall and the head of 

the screw.

Fig. 2

2.  

Überprüfen Sie, dass die Zuleitung span-

nungslos ist, um die Ofenzuleitung an-

zuschließen.

 First unscrew the four screws 

shown in Fig. 3 and then pull down the ter-

minal strip. See Fig. 3a.

Abb. 3

Abb. 3a

35 x 11 cm

70,5 cm

33 cm

16 cm

44,7 cm

min. 7 cm

Note:

The sauna heating unit is designed for a default 

supply voltage of 400 V AC 3N. 

Connection to a 230V 1N AC power supply is 

only possible with a compatible version and 

under observation of a special connection 

scheme.

Cabin wall

Protective grating for heater

Air intake opening   mandatory

requirement 
in the middle of the collection 

well

Fixing screws for cover plate

Hinweis:

Das Saunaheizgerät ist für eine Standardversor-

gungsspannung von 400 V AC 3N ausgelegt.

Der Anschluss an eine 230 V 1 N Wechselstrom-

versorgung ist nur mit einer kompatiblen Ver-

sion und unter Beachtung eines speziellen An-

schlussschemas möglich.

Содержание Filius Control

Страница 1: ...INNOVATIVE SAUNA TECHNOLOGY MADE IN GERMANY Druck Nr 29345062 en 18 19 Filius Control 400 V 3N AC 230 V 1N AC EN Installlation and operating instruction...

Страница 2: ...ications 6 Connection example 400 V 3N 8 Connection example 230 V 1N 9 Installation of the Filius Control 10 Minimum distances 10 Commissioning 12 Position change control panel left right 13 Replaceme...

Страница 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...

Страница 4: ...eofsuitable low resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each saun...

Страница 5: ...floor On heaters with bases this clearance is maintained via the base or legs of the device Floor heating in the sauna cabin increases the surface temperature of the flooring Please see the dimension...

Страница 6: ...able exits the sauna heater and guide this cable outside through the hole to the control unit The cable and all other connecting cables mains power cables and cabin lighting should be installed in ins...

Страница 7: ...AC Anschluss an 230V 1NWechselstrom m glich Power rating 4 5 kW 6 0 kW 7 5 kW For sauna size 4 6 m 6 8 m 7 10 m Min size air inlet and exhaust vent 35 x 11 cm Weight without stones and packing 15 kg...

Страница 8: ...ite Connection example for 400V 3N AC 4 5 kW 3x 1500 W 6 0 kW 3x 2000 W 7 5 kW 3x 2500 W Power acc DIN Electrical connection Fuse protection Connecting cable main heater 4 5 kW 400V 3N AC 50 Hz 3 x 16...

Страница 9: ...re given for 230V 1N power supply Specifications for 230V 1N connection 4 5 kW 3x 1500 W 6 0 kW 3x 2000 W 7 5 kW 3x 2500 W A1 A2 A3 B1 B2 B3 Thermostat Sicherheits temperaturbegrenzer M Zeitschaltuhr...

Страница 10: ...all so that there is approx 3 mm space between the wall and the head of the screw Fig 2 2 berpr fen Sie dass die Zuleitung span nungslos ist um die Ofenzuleitung an zuschlie en First unscrew the four...

Страница 11: ...and the two lock screws U V W N N PE N Z Y X L N PE 230V AC A Strahlblech U V W N N PE N Z Y X 400V 3N AC Fig 4 1 Connection line Screws 4 2 x 9 5 Corrugated head screws 2 9 x 19 Connection terminal...

Страница 12: ...necessary The design of the cabin can impact on the way the cabin heats up and cause tem perature differences of up to 15 C Also many bimetal thermometers wall moun ted react sluggishly so that the re...

Страница 13: ...13 EN Position change control panel left right safety screw 2 9 x 19 Fig 1 Fig 2 Fig 3 Fig 5 Fig 4 2 1 6 180 4 7 8 9 3 10 5...

Страница 14: ...14 EN Replacement of heating elements Fig 1 Fig 2 Fig 4 Fig 3 1 3 2 6 7 4 5...

Страница 15: ...more essences or volatile oils than advised on the packaging Never use alcohol or undiluted concentrates Cau tion Fire hazard All sauna heating units are made of low corro sion material To enjoy your...

Страница 16: ...l units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air It...

Страница 17: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Страница 18: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Отзывы: