Manual specifi cation of the lighting:
The control system recognises inductive loads via a voltage rise and then switches from
phase control to phase cut-off. If there are recognition problems, the phase control type can
be defi ned manually.
Only a specialist from an authorised specialist company may carry out this work!
1. Disconnect the lighting from the control system
2. Switch the control system on.
3. Go to the menu for setting the light intensity by pressing the
button for >3s
4. Now you can confi gure the light output:
a. Phase cut-off for capacitative and resistive loads: Press
MODE
+
at the same time,
display
R,C
in the display
b. Phase cut-off for inductive loads: Press
MODE
+
at the same time, display
L
in the
display
c. Automatic recognition: Press
MODE
+
at the same time, display
R, C / L AUTO
in the
display
5. Save the setting by pressing the
MODE
button for >3s
6. Switch the control system off
7. Connect the lighting again