31
GB
Extend heat-up time restriction / replace device fuse
By altering a jumper you can extend the heat-up restriction from 6:00 (standard) to 12:00 hours or
"indefi nite". Please note that extensions are only allowed in certain commercially operated sauna
systems.
Loosen the four screws on the opened unit that hold the circuit board.
Load board D4
Unit fuses
F1 = T 2A
Fuse electronics primary and light and fan
F2 = T 315 mA
Fuse of the electronics secondary
Jumper
6:00 hours heat-up time restriction (default setting)
Jumper
12:00 hours heat-up time restriction
Jumper
without heat-up time restriction (set auto-stop to - - : - - )
Only allow a specialist to carry out this work. Before working on the open control
unit, disconnect all poles from the mains. (Switch off the master switch, or trigger the FI
switch).
Risk of an electrical shock!
Loosen screws
Jumper for the heat-up time restriction (6 hours default setting)
F1
X2
F2
Loosen screws
Control board
F1
F2