3
For the mounting of the control unit, the
mounting holes Ø3 are drilled in accordance
with the dimensions given in Illust. 3, and
one of the provided wood screws 4 x 20, see
Illust. 3.1, is screwed into the wood through
the upper middle hole, leaving a 3mm
section of the screw projecting out from the
wall. The lower part of the control unit is
hooked onto this wood screw by its upper
mounting hole. Finally all connecting lines-
see Illust. 4-are conducted through the
respective feed-through conduits into the
control unit. The lower part is finally fastened
to the cabin wall through the two lower pre-
drilled holes.
If the sauna cabin is not equipped with
cable conduits for the connecting lines,
these lines must be laid directly onto the
cabin wall, where they will be visible. For
this purpose, the three mounting holes
must be pre-drilled, as shown in Illust. 3.
Finally, align the lower part of the control unit
over the drilled holes and sketch the right-
hand feed- through hole for the sensor lines
onto the cabin wall. Drill a roughly 10 mm
feed-through hole at this spot.
Because the connecting lines must be laid
between the control unit and the cabin wall
in this type of installation, for practical
purposes in a recess of the grooved panels,
the control unit must be installed in such a
way as to provide for adequate clearance.
For this purpose, 3 spacer tubes are
provided with the control unit. Using these
tubes, the lower part is installed to provide
for this clearance as shown in Illust. 3.2.
After the connecting lines are fed through
the respective feed-through channels into
the control unit, bolt the lower part, again
with help of the spacers, into the lower
mounting holes on the cabin wall.
Illust. 3
Illust. 3.2
Illust. 3.1
Illust. 4
Feed-through
channel for
sensor line
Feed-through
channel for lamp
Mounting holes
Feed-through
channel for oven
supply line
Feed-through
channel for
power supply lines
Mounting hole
english
At delivery, the capillary tube sensors may be
found in the control unit. Unroll the sensors
carefully and pull them through the afore
drilled hole into the cabin.The capillary tubes
must not be bent or damaged. The smallest
bending radius should not be less than 3-4
cm during and after installation. Pull the
capillary tubes completely into the cabin. No
excessive length should be in the control unit.