For the mounting of the control unit, the
mounting holes Ø3 are drilled in accordance
with the dimensions given in Illust. 3, and
one of the provided wood screws 4 x 20,  see
Illust. 3.1, is screwed into the wood through
the upper middle hole, leaving a 3mm
section of the screw projecting out from the
wall.  The lower part of the control unit is
hooked onto this wood screw by its upper
mounting hole.  Finally all connecting lines-
see Illust. 4-are conducted through the
respective feed-through conduits into the
control unit.  The lower part is finally fastened
to the cabin wall through the two lower pre-
drilled holes.

If the sauna cabin is not equipped with
cable conduits for the connecting lines,
these lines must be laid directly onto the
cabin wall, where they will be visible.  For
this purpose, the three mounting holes
must be pre-drilled, as shown in Illust. 3.
Finally, align the lower part of the control unit
over the drilled holes and sketch the right-
hand feed- through hole for the sensor lines
onto the cabin wall.  Drill a roughly 10 mm
feed-through hole at this spot.

Because the connecting lines must be laid
between the control unit and the cabin wall
in this type of installation, for practical
purposes in a recess of the grooved panels,
the control unit must be installed in such a
way as to provide for adequate clearance.
For this purpose, 3 spacer tubes are
provided with the control unit.  Using these
tubes, the lower part is installed to provide
for this clearance as shown in Illust. 3.2.
After the connecting lines are fed through
the respective feed-through channels into
the control unit, bolt the lower part, again
with help of the spacers, into the lower
mounting holes on the cabin wall.

Illust. 3

Illust. 3.2

Illust. 3.1

Illust. 4

Feed-through
channel for
sensor line

Feed-through
channel for lamp

Mounting holes

Feed-through
channel for oven
supply line

Feed-through
channel for
power supply lines

Mounting hole

english

At delivery, the capillary tube sensors may be
found in the control unit. Unroll the sensors
carefully and pull them through the afore
drilled hole into the cabin.The capillary tubes
must not be bent or damaged. The smallest
bending radius should not be less than 3-4
cm during and after installation. Pull the
capillary tubes completely into the cabin. No
excessive length should be in the control unit.

Содержание ECON 09

Страница 1: ...1 Installation and User s Guide ECON 09 IP x4 GB DruckNr 29343276en 37 06 ...

Страница 2: ...e control panel dials as captive screws but may be screwed open and closed through the visible holes in the operating panel with a small Phillips screwdriver After the screws are loosened the cover is removed For practical purposes the control unit should always be fastened to the outer wall of the cabin to which the sauna oven inside the cabin is also attached Please observe that most sauna cabin...

Страница 3: ...pot Because the connecting lines must be laid between the control unit and the cabin wall in this type of installation for practical purposes in a recess of the grooved panels the control unit must be installed in such a way as to provide for adequate clearance For this purpose 3 spacer tubes are provided with the control unit Using these tubes the lower part is installed to provide for this clear...

Страница 4: ...nt Lead the oven connecting cable through this hole to the outside install a distribution box near the air intake vent which is suitable for use in wet areas lay a 5 wire power supply lead between distibution box and control unit connect in the distribution box with the silicon connecting line in accordance with the wiring diagram The minimum diameter of the connecting line is shown in the chart b...

Страница 5: ...ack the sensors into the control unit under any circumstances Operation of the sauna system is started with the left hand timer switch The maximum activation time is 4 hours due to safety precautions During this time the green signal lamp lights up After 4 hours the sauna oven and the cabin light will shut itself down The cabin temperature is pre selected with the right hand thermostat dial The to...

Страница 6: ...electrician Note Is there a problem reaching the required bathing temperature or is the temperature different from that indicated on the thermometer in the cabin Please note that the temperature sensor is positioned in the area of the heating system The thermometer is always located in a different place for ex on the back wall of the cabin over the recliner bench The sensor however canonlymeasuret...

Страница 7: ...en red a1 b1 b a english Press the 3 locking pins behind the connecting plug until you feel a switching point Close the control unit again before setting up operation In case the temperature limiter should cut off again immediately after taking into operation the unit has to be checked by a specialist 3 locking pins behind connecting plug Temperature limiter for security L1 L2 L3 L1 L2 L3 ...

Страница 8: ...other suitable packaging caution danger of transport damage to our service department Always include the completed warrenty certificate when returning equipment Possible shipping costs arising from the transport to and from point of repair cannot be borne by us Outside of Germany please contact your specialist dealer in case of warranty claims Direct warranty processing with our service department...

Отзывы: