Mounting
Installing the air inlet in the middle of the cabin
Air outlet
The air outlet must meet the following criteria:
Location: Across from the heater
Height: 30–50 cm above the cabin floor
3.1.3 Connection cables
The heater must be connected to the relay boxes with four connection
cables. Install the cables in such a way that they are protected from dam-
age. To do this, route empty pipes from the installation site of the heater to
the relay boxes.
Two cables must be routed to each terminal box.
Outside of the cabin, the cables must be routed under a suitable protective
cover (e.g. in a cable duct or empty conduits).
See the connection diagram
Connection diagram for connecting MEGA
3.2 Specifications for the control unit
Observe the operating conditions for the control unit to ensure that the
sauna cabin's temperature control works properly. The installation site
must be selected accordingly. Specifications can be found in the installa-
tion instructions for the control unit or in the instructions provided by the
manufacturer of the control unit.
3.3 Installing the temperature sensor in the cabin
The temperature sensor should be mounted in the middle and flush with
the long side of the heater; see
Dimensions in the cabin (in cm),