14
Installation and Operating Instructions - MEGA
Mounting
EN
Mounting
This chapter describes how to install MEGA. Prior to installing the unit, air
inlets and outlets must be attached to the cabin. It may be necessary to
mount additional fans in the inlets/outlets. All protective films must be
removed.
NOTICE
Damage due to incorrect mounting location
The heater is not suitable for outdoor use.
The heater must be operated only inside buildings and may not
be exposed to environmental conditions such as extreme hu-
midity and moisture or the possible formation of condensation
or corrosive substances in the ambient air, as well as other
weather conditions.
The heater is not designed to be installed or set up in an alcove
or under a bench or sloping roof.
3.1 Specifications for the cabin
The cabin must be planned and installed according to specifications before
the heater is installed.
All electrical installations laid inside the cabin must be suitable for a tem-
perature of at least 170°C.
All lines must be routed in such a way that they are well-protected, e.g. in a
cable conduit.
In general, it should be noted that the sauna heater must not be set on a
floor made of highly flammable material (wood, flooring made of plastic
material, etc.). Ceramic tiles are well suited as a flooring option.
Floor heating in the sauna cabin increases the temperature of the floor's
surface temperature.
3.1.1 Installation site
Ceiling height of at least 250 cm
Distance between heater and cabin wall at least 12 cm
Distance between heater and bench at least 12 cm
The required cabin volume depends on the heater output.
See 2.4 Technical data,