EOS Compact DC/HC - Installation and Operating Instructions
EN-15
Identification
Humidity control
(HC only)
Without humidity sensor: Cycle (1–100) in proportion
to time for active humidity mode
With humidity sensor: according to relative air humid-
ity in %
Water level monitoring
(HC only)
Detects water shortage with automatic switch off after
3 minutes (only with compatible sauna heater)
Connection for lighting
Min. 5 W (20 mA)
Resistive load: max. 100 W
Energy-saving bulbs, max. 35 W
Light source with conventional transformers, max.
60 VA.
Fan and light connections are protected by a joint 2A F
fuse.
Light dimming
Possible for light sources with phase-cut dimmer.
Resistive loads (e.g. light bulbs) and inductive loads
(e.g. LED light source) are suitable. Capacitive loads
(phase control) are not supported.
Connection for fan
Max. 100 W
Sensor system
(Temperature)
KTY sensor with
safety temperature limiter 139°C
Temperature display for
heater sensor
Current value at heater sensor minus 7 K to offset
higher temperatures directly under the cabin ceiling
Temperature display for
bench sensor, multisen-
sor
Current value at bench sensor, multisensor
Display for humidity
multisensor
Current value at multisensor
Heating period limita-
tion
6 hrs (factory setting), 12 hrs, 18 hrs, infinite
Technical data