enware DET5072A-CNBSN Скачать руководство пользователя страница 9

www.enware.com.au                                                                                                                                                                              Call 1300 369 273   

 9  

installation in-wall

MOUNTING THE SENSOR PLATE

The stainless steel sensor plate is always 

mounted flush to the wall. Feed the 

transformer cable through the conduit and 

make the connection to the sensor by joining 

the line plug and socket, observing the polarity 

of the plug.

Fix the sensor panel using four screws 

provided.

 WARNING:

  Sensor components are fragile and sensitive. 

Do not force the sensor plate to fit onto wall, 

or attempt to disassemble sensor components, 

as this could result in damage to sensor and 

would void warranty.

INSTALLING THE SPOUT

Apply thread sealant on 1/2” BSP male thread. 

Screw on the wall base with a spanner and 

fix onto plate with the back nut. Loosen grub 

screw on the spout, slide onto wall base, then 

tighten the grub screw to fix the spout in 

position.

Connect water supply from the outlet of the 

solenoid to the spout.  

TESTING

Turn on the power to the unit and test the unit. 

See Operating Instructions overpage.

TESTING

Turn the water on and check for leaks. Connect all electrical components together temporarily, 

 

and test the tap.  Once correct operation of the tap is confirmed, disconnect the sensor plate and turn 

off the power to the transformer. The tap is now ready for sheeting or finishing of the wall.

installation after the wall is finished   

IMPORTANT: 
Before fixing the sensor plate to wall, 

apply a thin bead of silicone sealant 

behind the plate along the top and 

side edges. Ensure that the plate is 

thoroughly sealed to the wall and that 

no water can get in behind the plate. 
Any water entering behind the sensor 

plate will cause damage to sensor 

components and void warranty.

APPLY 

THREAD TAPE

TR-20 TORX

Содержание DET5072A-CNBSN

Страница 1: ...alia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph 02 8536 4000 info enware com au Wall Mounted Sensor Tap Hands Free On Off Demand Sensor with Custodian Basin Spout Installation and Main...

Страница 2: ...beam for the unit to keep the valve open If the solenoid valve remains open for more that 45 seconds the unit will time out and close the valve automatically This is intended to conserve water and pr...

Страница 3: ...t complying with PCA and AS NZS 3500 may void the product and performance warranty provisions Reference should also be made to the Australasian Health Facility Guidelines AHFG ABCB and Local Governmen...

Страница 4: ...fectively blinded and will not operate Up to 1 5 metre clearance may be necessary from reflective surfaces such as ceramic tiles and stainless steel directly in front of and parallel to the front face...

Страница 5: ...ithout using the correct lead extension from Enware as this will void warranty BEFORE CONNECTING WATER SUPPLY Ensure all supply lines are flushed thoroughly to remove debris prior to the installation...

Страница 6: ...olenoid and an isolation valve and a mesh strainer should be fitted before the solenoid for ease of servicing and trouble free solenoid operation SEE IMAGE 01 installation ISOLATION VALVE AND MESH STR...

Страница 7: ...to the outlet side of the solenoid and supply line to the inlet side of the solenoid SEE IMAGE 01 INSTALLING THE SENSOR BRACKET Once the position of the spout and sensor plate is determined fix the s...

Страница 8: ...f Solenoid Cable are pre wired to the cable plug to connect to the two side terminals on solenoid Earth terminal on top connector is not used SEE IMAGE 07 SOLENOID CONNECTION Connect here Connect here...

Страница 9: ...t slide onto wall base then tighten the grub screw to fix the spout in position Connect water supply from the outlet of the solenoid to the spout TESTING Turn on the power to the unit and test the uni...

Страница 10: ...e hand in front of sensor lens for half a second at a distance of 5 cm Move hand away Water starts to flow TO TURN OFF Place hand in front of sensor lens for half a second at a distance of 5 cm Move h...

Страница 11: ...er does not turn on when hand is within sensor range Red LED does not light up in the sensor lens Power supply is off or transformer is damaged Turn power on or replace transformer Sensor is damaged R...

Страница 12: ...DC 24v with 4 5m lead EMDS802 Sensor Connector Cable 0 1m 673830 Solenoid Cable 3m 673829 2m Extension Cable for Transformer or Solenoid EMDS801 4 5m Extension Cable for Transformer or Solenoid 48022...

Страница 13: ...solenoid 3 The solenoid can be disassembled and checked for debris or damage to the diaphragm Refer to Servicing the Solenoid instructions below Take note of the location of the components so that it...

Страница 14: ...d Grease can deteriorate over time and cause the solenoid to malfunction 8 Reassemble the plunger with spring into the core tube Check that the spring is reassembled back together inside the core tube...

Страница 15: ...nsor Feed the cable back into the conduit 5 Apply a thin bead of silicon sealant on behind the plate along the top and side edges to seal the unit to the wall 6 Fix the sensor panel back onto the moun...

Страница 16: ...ou must notify us in writing within 7 days of any alleged defect in the product coming to your attention provide us with proof of your purchase of the product and have completed the Online Product Ser...

Отзывы: