installation in-wall

POWER PACK AND CABLES

It is recommended that all cabling is fed through 

20mm conduit to make servicing and replacement 

easier. The solenoid valve and power point/ 

transformer are generally located either in the wall 

space or in the ceiling but must be easily accessible 

for servicing. This may be through an access panel on 

the wall or the ceiling. 

 

The transformer has a 4.5 metre lead to the sensor and 

the solenoid cable has a 3 metre lead from the sensor 

to the solenoid. Additional lead lengths up to 15 metres 

can be accommodated with extension cables (available 

separately from Enware).

 

SEE IMAGE 06

Plug the 24V DC transformer into the 240V AC power 

point. 

Connect Transformer Cable to Sensor Connector 

Cable. 
Connect Solenoid Cable to Sensor Connector Cable. 

The two connectors of Solenoid Cable are pre-wired to  

the cable plug, to connect to the two side terminals 

on solenoid. Earth terminal on top connector is not 

used. 

SEE IMAGE 07

 

SOLENOID CONNECTION

Connect

here

Connect

here

Earth Connecon

NOT USED

IMAGE 07

INSTALL A CONDUIT

TO ALLOW FOR FUTURE

SERVICING OF CABLES

3m

0.1m

SENSOR 

CONNECTOR 

CABLE

SOLENOID

CABLE

1m

POWER SUPPLY

4.5m

TRANSFORMER CABLE

IMAGE 06

WARNING: Do not cut the electrical cable of 

the sensor tap, or alter the product in any 

way to suit installation. Damage caused in 

this way will void warranty. Cable extensions 

are available if extra cable length is required. 

 

(Refer to Spare Parts Section)

WARNING: Protecting from Water Spray

Note that the power pack and connections are NOT spray or water 

proof. If there is a possibility of water coming into contact with 

any of the electrical components or connections (e.g. if electrical 

components are exposed underneath a basin), the unit and all of the 

interconnections should be installed into a water-proof enclosure. 

WIRING METHOD

  

SEE IMAGE 06 AND 07

 

Содержание DET5072A-CNBSN

Страница 1: ...alia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph 02 8536 4000 info enware com au Wall Mounted Sensor Tap Hands Free On Off Demand Sensor with Custodian Basin Spout Installation and Main...

Страница 2: ...beam for the unit to keep the valve open If the solenoid valve remains open for more that 45 seconds the unit will time out and close the valve automatically This is intended to conserve water and pr...

Страница 3: ...t complying with PCA and AS NZS 3500 may void the product and performance warranty provisions Reference should also be made to the Australasian Health Facility Guidelines AHFG ABCB and Local Governmen...

Страница 4: ...fectively blinded and will not operate Up to 1 5 metre clearance may be necessary from reflective surfaces such as ceramic tiles and stainless steel directly in front of and parallel to the front face...

Страница 5: ...ithout using the correct lead extension from Enware as this will void warranty BEFORE CONNECTING WATER SUPPLY Ensure all supply lines are flushed thoroughly to remove debris prior to the installation...

Страница 6: ...olenoid and an isolation valve and a mesh strainer should be fitted before the solenoid for ease of servicing and trouble free solenoid operation SEE IMAGE 01 installation ISOLATION VALVE AND MESH STR...

Страница 7: ...to the outlet side of the solenoid and supply line to the inlet side of the solenoid SEE IMAGE 01 INSTALLING THE SENSOR BRACKET Once the position of the spout and sensor plate is determined fix the s...

Страница 8: ...f Solenoid Cable are pre wired to the cable plug to connect to the two side terminals on solenoid Earth terminal on top connector is not used SEE IMAGE 07 SOLENOID CONNECTION Connect here Connect here...

Страница 9: ...t slide onto wall base then tighten the grub screw to fix the spout in position Connect water supply from the outlet of the solenoid to the spout TESTING Turn on the power to the unit and test the uni...

Страница 10: ...e hand in front of sensor lens for half a second at a distance of 5 cm Move hand away Water starts to flow TO TURN OFF Place hand in front of sensor lens for half a second at a distance of 5 cm Move h...

Страница 11: ...er does not turn on when hand is within sensor range Red LED does not light up in the sensor lens Power supply is off or transformer is damaged Turn power on or replace transformer Sensor is damaged R...

Страница 12: ...DC 24v with 4 5m lead EMDS802 Sensor Connector Cable 0 1m 673830 Solenoid Cable 3m 673829 2m Extension Cable for Transformer or Solenoid EMDS801 4 5m Extension Cable for Transformer or Solenoid 48022...

Страница 13: ...solenoid 3 The solenoid can be disassembled and checked for debris or damage to the diaphragm Refer to Servicing the Solenoid instructions below Take note of the location of the components so that it...

Страница 14: ...d Grease can deteriorate over time and cause the solenoid to malfunction 8 Reassemble the plunger with spring into the core tube Check that the spring is reassembled back together inside the core tube...

Страница 15: ...nsor Feed the cable back into the conduit 5 Apply a thin bead of silicon sealant on behind the plate along the top and side edges to seal the unit to the wall 6 Fix the sensor panel back onto the moun...

Страница 16: ...ou must notify us in writing within 7 days of any alleged defect in the product coming to your attention provide us with proof of your purchase of the product and have completed the Online Product Ser...

Отзывы: