![enware DET5072A-CNBSN Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/enware/det5072a-cnbsn/det5072a-cnbsn_installation-and-maintenance-instructions-manual_2416472008.webp)
8
Call 1300 369 273
www.enware.com.au
installation in-wall
POWER PACK AND CABLES
It is recommended that all cabling is fed through
20mm conduit to make servicing and replacement
easier. The solenoid valve and power point/
transformer are generally located either in the wall
space or in the ceiling but must be easily accessible
for servicing. This may be through an access panel on
the wall or the ceiling.
The transformer has a 4.5 metre lead to the sensor and
the solenoid cable has a 3 metre lead from the sensor
to the solenoid. Additional lead lengths up to 15 metres
can be accommodated with extension cables (available
separately from Enware).
SEE IMAGE 06
Plug the 24V DC transformer into the 240V AC power
point.
Connect Transformer Cable to Sensor Connector
Cable.
Connect Solenoid Cable to Sensor Connector Cable.
The two connectors of Solenoid Cable are pre-wired to
the cable plug, to connect to the two side terminals
on solenoid. Earth terminal on top connector is not
used.
SEE IMAGE 07
SOLENOID CONNECTION
Connect
here
Connect
here
Earth Connecon
NOT USED
IMAGE 07
INSTALL A CONDUIT
TO ALLOW FOR FUTURE
SERVICING OF CABLES
3m
0.1m
SENSOR
CONNECTOR
CABLE
SOLENOID
CABLE
1m
POWER SUPPLY
4.5m
TRANSFORMER CABLE
IMAGE 06
WARNING: Do not cut the electrical cable of
the sensor tap, or alter the product in any
way to suit installation. Damage caused in
this way will void warranty. Cable extensions
are available if extra cable length is required.
(Refer to Spare Parts Section)
WARNING: Protecting from Water Spray
Note that the power pack and connections are NOT spray or water
proof. If there is a possibility of water coming into contact with
any of the electrical components or connections (e.g. if electrical
components are exposed underneath a basin), the unit and all of the
interconnections should be installed into a water-proof enclosure.
WIRING METHOD
SEE IMAGE 06 AND 07