installation in-wall
66mm min.
78mm max.
193mm
120mm
Wall Cut Out
for Sensor Bracket
IMAGE 04
IMAGE 05
IMAGE 02
Note: Ensure the solenoid is installed in the correct
direction. The arrow on the solenoid body must align
with the direction of water flow.
SEE IMAGE 02
The black casing for solenoid can be turned around
to suit the direction of wiring connection, by first
loosening the hex nut on top.
SEE IMAGE 03
Connect outlet line to the outlet side of the
solenoid, and supply line to the inlet side of the
solenoid.
SEE IMAGE 01
INSTALLING THE SENSOR BRACKET
Once the position of the spout and sensor plate is
determined, fix the sensor mounting bracket inside
wall. Take note of the maximum and minimum
depths for the sensor.
SEE IMAGE 04
Minimum wall depth 66mm, maximum 78mm.
Wall Cut Out Dimensions
Before the wall is sheeted or finished, allow for a
cut out in the finished wall surface, of 193mm wide
x 120mm high rectangular hole, and at least 65mm
deep to allow for installation of bracket. Sensor
cable to come through the top, bottom, or back of
sensor inside wall.
SEE IMAGE 05