background image

KUDOS RANGE CENTRIFUGAL EXTRACTOR FANS 

Suitable for bathroom, kitchen and utility room applications 

 

Thank you for placing your confidence in 

EnviroVent

 by buying this product. It 

has been manufactured in accordance with current technical safety regulations, 
production and quality standards as laid down by the international Quality      
Standard ISO 9001. Please read this instruction booklet carefully before installing 
or operating the product. It contains important information on personal and user 
safety  measures  to  be  followed  whilst  installing,  using  and  carrying  out          
maintenance work on the equipment. Once the product has been installed, please 
pass this booklet to the end user. 
 
Check that the product is in perfect condition whilst unpacking. Any fault or      
damage caused in origin is covered by the 

EnviroVent

 guarantee. Please make 

sure that the product corresponds to the one you have ordered and that the     
details on the instruction label fulfil your requirements. 

 
 
 

IMPORTANT:  

 
BE SURE TO HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BEFORE 
BEGINNING THE INSTALLATION PROCESS 

 

 
 
SAFETY AND RECOMMENDATIONS 

 

x

All wiring must comply with Building Regulations and the current I.E.E. Wiring 
Regulations (BS7671) or the equivalent standards for your country. The final      
installation should be examined and tested by a competent person. This fan is IP44 
rated. 

x

Do not install near sources of heat in excess of 40°C.

 

x

It is recommended that a flexible cable is used to connect the fan connector      
terminals 

x

Position away from any source of water spray from a bath or shower. Do not site in 
a shower enclosure.  

x

Position the fan at the furthest distance from the main source of air replacement in 
the room in order to achieve maximum airflow performance.  

x

Ducted Applications. 

In circumstances where an excessive amount of moisture is 

present in the air, then a condensation trap will need to be installed in the exhaust 
duct. 

Horizontal ducts should fall away from the fan unit

. Ducts passing 

through an unheated roof void should be insulated.  

x

This appliance is not intended for use by young children or infirm persons unless 
they have been adequately supervised by a responsible person to ensure that they 
can use the appliance safely. Young children should be supervised to ensure that 
they do not play with the appliance. 

Содержание kudos

Страница 1: ...KUDOS Instruction leaflet...

Страница 2: ...NSTALLATION PROCESS SAFETY AND RECOMMENDATIONS x All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final...

Страница 3: ...INSTALLATION KUDOS 1 2 3 4 6 7 6 7 5 8 Fig 1 Fig 2A Fig 2B 9 3 Fig 1B...

Страница 4: ...Fig 3 Fig 5A Fig 6A N LA LB Fig 4 L N N A L B L L N N LA LB Fig 5B L C N N A L LB L N REB N A L LB Fig 6B EBB S KUDOS S...

Страница 5: ...Fig 9A Fig 7A L N N L LS L N N L LS N L LS N L LS 15 30 A 2 T min 80 90 70 60 T min HR 20 30 1 10 L N N L LS Fig 7A Fig 7B EBB T EBB HT L N N L LS Fig 8A Fig 8B Fig 9B KUDOS HT KUDOS T...

Страница 6: ...s taught as possible x Do not fix elbow bends directly to the spigot assembly x Elbow bends should have a radius as large as possible Panel Installation Surface Mounting Fig 2A 1 Cut a 105mm hole thro...

Страница 7: ...is working correctly Wall Installation Surface Mounting Using 100mm EnviroVent Wall Kit 1 Drill a 115mm hole through the wall ensuring sufficient space for the fan to be installed 2 Insert the wall s...

Страница 8: ...operation with a switch Fig 6B Fan operating with an REB variable speed controller KUDOS T Models with adjustable timer The timer enables the fan to operate for the time set after the switch has been...

Страница 9: ...tion with a light switch Fig 8B The fan will operate even if the humidity level is below the set value When the light switch is turned off the fan will continue to operate at slow speed for the length...

Страница 10: ...ated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd Envirovent Ho...

Страница 11: ......

Страница 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023013701...

Отзывы: