background image

10. Close the terminal block flap and secure with the screw. 
11. By pressing the upper and lower clips, fit the front cover back onto the fan body. 
12. Switch the mains power supply on and check that the fan is working correctly. 
 

Panel Installation

Recess Mounting (Fig. 2B) 

 

1. 

Using the template supplied, mark out and cut a hole in the panel. 

Read  the           

instructions on the template sheet carefully.  

2. 

Fig. 1B - By pushing the clip using a small screwdriver pull the front cover (1) 
away from the fan body (2). 

3. 

The fan body (2) is secured to the base frame (4) by 4 screws. Take out each 
screw from the four corners (6) to dismantle and release the base frame.  

4. 

Take out the screw that secures the terminal block flap (5) to the fan body (2). 

5. 

Fig. 4. - For side exit installations, the spigot assembly (9) can be repositioned. To 
do this, remove the spigot assembly (9) from the fan body (2). Rip off the guide 
vane (8) from the fan body and reattach the spigot in a side orientation in the    
desired direction.  

6. 

Attach the ducting to the spigot (9). 

7. 

Feed the cable through the hole in the terminal block (Fig. 3) 

8. 

Using appropriate fixtures, screw the fan body (2) into the hole in the panel. 

9. 

Follow instructions for 

Electrical Connections and Wiring in B.

 

10.      Close the terminal block flap and secure with the screw. 
11.      By pressing the upper and lower clips, fit the front cover back onto the fan body. 
12. 

Switch the mains power supply on and check that the fan is working correctly. 

 

Wall Installation

Surface Mounting 

Using 100mm EnviroVent Wall Kit. 
 
1. 

Drill a Ø115mm hole through the wall, ensuring sufficient space for the fan to be 

installed. 

2. 

Insert the wall sleeve with the wider diameter sleeve facing the room side and 
cement both ends in place, flush with the wall. The wall sleeve must be angled 
downwards to drain any condensation to outside. 

3. 

To fix the outside grille, use the back plate as a template and mark the fixing holes  
on the wall. Drill and plug the wall to fix the back plate securely into position.  

4. 

Secure the outside grille onto the back plate with the screws provided, making 
sure that the louvers are directed downwards. 

5. 

Fig. 1B - By pushing the clip using a small screwdriver pull the front cover (1) 
away from the fan body (2). 

6. 

The fan body (2) is secured to the base frame (4) by 4 screws. Take out each 
screw from the four corners (6) to dismantle and release the base frame.  

7. 

Screw the base frame (4) to the wall using appropriate fixtures ensuring that the 
opening for the spigot lines up correctly with the hole made when the fan body is 
re-attached. 

8. 

Take out the screw that secures the terminal block flap (5) to the fan body (2). 

9. 

Feed the cable through the hole in the terminal block (Fig. 3). 

10. 

Reassemble the fan body (2) to the base frame (4) and secure with 4 screws 

11. 

Follow instructions for 

Electrical Connections and Wiring in B.

 

12.      Close the terminal block flap and secure with the screw. 
13.      By pressing the upper and lower clips, fit the front cover back onto the fan body. 
14.      Switch the mains power supply on and check that the fan is working correctly 
 

Содержание kudos

Страница 1: ...KUDOS Instruction leaflet...

Страница 2: ...NSTALLATION PROCESS SAFETY AND RECOMMENDATIONS x All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final...

Страница 3: ...INSTALLATION KUDOS 1 2 3 4 6 7 6 7 5 8 Fig 1 Fig 2A Fig 2B 9 3 Fig 1B...

Страница 4: ...Fig 3 Fig 5A Fig 6A N LA LB Fig 4 L N N A L B L L N N LA LB Fig 5B L C N N A L LB L N REB N A L LB Fig 6B EBB S KUDOS S...

Страница 5: ...Fig 9A Fig 7A L N N L LS L N N L LS N L LS N L LS 15 30 A 2 T min 80 90 70 60 T min HR 20 30 1 10 L N N L LS Fig 7A Fig 7B EBB T EBB HT L N N L LS Fig 8A Fig 8B Fig 9B KUDOS HT KUDOS T...

Страница 6: ...s taught as possible x Do not fix elbow bends directly to the spigot assembly x Elbow bends should have a radius as large as possible Panel Installation Surface Mounting Fig 2A 1 Cut a 105mm hole thro...

Страница 7: ...is working correctly Wall Installation Surface Mounting Using 100mm EnviroVent Wall Kit 1 Drill a 115mm hole through the wall ensuring sufficient space for the fan to be installed 2 Insert the wall s...

Страница 8: ...operation with a switch Fig 6B Fan operating with an REB variable speed controller KUDOS T Models with adjustable timer The timer enables the fan to operate for the time set after the switch has been...

Страница 9: ...tion with a light switch Fig 8B The fan will operate even if the humidity level is below the set value When the light switch is turned off the fan will continue to operate at slow speed for the length...

Страница 10: ...ated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd Envirovent Ho...

Страница 11: ......

Страница 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023013701...

Отзывы: