Specifications
C
LEARANCES
T
O
C
OMBUSTIBLES
- 1200 F
REESTANDING
:
MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*
Table 3: 1200 Freestanding Clearance to Combustibles.
Single Wall Pipe
Double Wall Pipe**
Double Wall Pipe
with Heat Effi ciency
Shield 50-1088 (Flat
top model only)
Top vent out back
wall with min. 24”
(610 mm) vertical
rise; double wall
A
From side wall
to side of unit
13”
(330 mm)
13”
(330 mm)
13”
(330 mm)
14”
(356 mm)
B
From rear wall
to back of unit
11”
(279 mm)
10”
(254 mm)
8”
(203 mm)
12”
(305 mm)
C
From adjacent wall
to corner of unit
9”
(229 mm)
8”
(203 mm)
6½”
(165 mm)
D
From side wall
to collar
22”
(559 mm)
22”
(559 mm)
22”
(559 mm)
23”
(584 mm)
E
From rear wall
to collar
14”
(356 mm)
13”
(330 mm)
11”
(279 mm)
15”
(381 mm)
F
From adjacent wall
to collar
17½”
(445 mm)
16½”
(419 mm)
15”
(368 mm)
G
† From door opening
to edge of hearth pad
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
H
† From side/back of unit
to edge of hearth pad
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
Alcove (48” [1220 mm] Deep)
I
Total Width
55” (1397 mm)
J
Total Height
78” (1981 mm)
K
Top of stove to ceiling
49” (1245 mm)
L
Side wall to stove
15” (381 mm)
M
Side wall to pipe
24” (610 mm)
N
Back wall to unit
12” (305 mm)
O
Back wall to pipe
15” (381 mm)
CAUTION:
An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed
space, or through a fl oor, ceiling, wall, or partition, or any combustible construction.
†
FLOOR PROTECTION:
If a stove is installed on a combustible fl oor, it must have a pedestal or leg kit with ash
pan attached and be on a NON-COMBUSTIBLE hearth pad
* ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.
**DOUBLE WALL:
IN CANADA: Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.
IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.
H
H
H
G
B
A
D
E
Front
Front
Hearth
K
J
Back wall
S
ide w
all
N
L
M
O
Front
Alcove Back wall
A
lc
o
v
e S
ide w
all
C
F
C
Fr
on
t
Adjacent wall
A
djac
en
t w
all
I
Alcove
PB