45

Initial Installation

QUALIFIED INSTALLERS ONLY

G

as

 L

ine

 c

onnection

 

anD

 t

estinG

:

WARNING: ONLY PERSONS LICENSED TO WORK WITH GAS PIPING MAY MAKE NECESSARY 

GAS CONNECTIONS TO THIS APPLIANCE.

• 

There is a 3/8 NPTM pipe located on the right side of the unit for the gas line connection. In Canada, 

consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code. In the USA, 

gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI 

Z223.1.

• 

The efficiency rating of this appliance is a total thermal efficiency rating determined under continuous 

operating conditions and was determined independently of any installed system.

The  appliance  and  its  shutoff  valves  must  be 

disconnected  from  the  gas  supply  piping  system 

during  any  pressure  testing  where  the  pressure 

exceeds ½ PSIG (3.45 KPa) or damage will occur 

to the valve.
The appliance must be isolated from the gas supply 

piping  system  by  closing  its  individual  manual 

shutoff valve during any pressure testing of the gas 

supply piping system at test pressures equal to or 

less than ½ psig (3.45 KPa).

Always  check  for  gas  leaks  with  a  soap 

and  water  solution  after  completing  the 

required pressure test.

TO TEST VALVE PRESSURES
The pressure taps are located on the top right of the valve shown in Figure 58.

• 

Turn set screw 1 turn counter clockwise to loosen, 

• 

Place 

5

/

16

” (8 mm)

 I.D. hose over pressure tap system. 

• 

Check pressures using a manometer.

• 

When finished, release pressure, remove hose & tighten set screw.

O

L

I

T

P

T

P

 T

H

      TP

T

H

IN

OUT

H I

L

O

N

OF

O

F

LI

P

T

O

Manifold

Pressure Tap

Inlet Pressure

Tap

Hi/Low

Knob

Pilot Adjustment

Screw

Gas Control 

Knob

Figure 58: Labeled Gas Valve.

Table 8: G42L Pressure and BTU Information

*Gas Valve will be 

mounted upside down on 

some models

G42L

Natural Gas

Propane Gas

Main Orifice

Front: #44 Rear: #46

Front: #53 Rear: #56

Manifold Pressure

3.6” W.C. (0.89 KPa)

10.0” W.C. (2.49 KPa)

Min. Manifold Pressure

1.6” W.C. (0.39 KPa)

6.4” W.C. (1.59 KPa)

Max Supply Pressure

7.0” W.C. (1.74 KPa)

11.0” W.C. (2.74KPa)

Min. Supply Pressure

4.5” W.C. (1.12 KPa)

10.4” W.C. (2.59 KPa)

Max BTU/hr Input

42,500 BTU/hr (12.5 kWh)

41,000 BTU/hr (12.0 kWh)

Min. BTU/hr Input

22,500 BTU/hr (6.6 kWh)

21,000 BTU/hr (6.2 kWh)

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

Содержание G42L

Страница 1: ...and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html C 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w...

Страница 2: ...immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service m...

Страница 3: ...st be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA...

Страница 4: ...duction 17 Unit Install Preparation 17 Placement and Framing 21 Vent Heat Shields 22 Cool Surface Framing 23 Cool Surface Activation 26 Floor Protection 27 Mantel Requirements 27 Flat Wall Installatio...

Страница 5: ...2017 CSA 2 33 2017 VENTED GAS FIREPLACE HEATERS CSA 2 17 2017 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This ENVIRO G42 Fireplace Has been certified for use with either natural gas or propane see ratin...

Страница 6: ...rtant information for your fireplace is on this label as well as the model specific serial number which you will need for warranty information The sheet is located inside the cabinet under the gas val...

Страница 7: ...to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in...

Страница 8: ...turned on for the first time it should be turned onto high with the fan OFF for the first two to four hours This will cure the paint logs gasket material and other products used in the manufacturing...

Страница 9: ...ty Read Safety Precautions And Lighting Instructions Before Operating Air Shutter Venturi The air shutter plays a very important role in flame appearence and combustion quality The shutter adjusts how...

Страница 10: ...he amount of use the glass should require cleaning no more than two or three times a season WARNING Do not clean the glass when it is hot Cleaning The Firebox Carefully remove the logs they are fragil...

Страница 11: ...uick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace Never clean the face when it is hot Do not use other cleaners as they may leave a residue which can become permanently et...

Страница 12: ...WARNING Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fireplace with the glass door removed Figure 8 Door Cover Removal Door Cover...

Страница 13: ...ss to the two lower T20 screws Once the specified screws are removed lift up to remove To re install the burners follow steps above in reverse When placing the burners back in the unit be sure not to...

Страница 14: ...ge personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper or complete until the operation of the converted a...

Страница 15: ...act your Enviro dealer Pilot Head 6 Convert the gas valve a Remove the black protection cap from the HI LO knob see Figure 15 b Remove the conversion screw using a 5 32 inch or 4mm Allen key see Figur...

Страница 16: ...in the valve see Figure 58 clockwise to decrese and counter clockwise to increase until the correct flame is achieved see Figure 3 12 Start the main burner and varify full range of adjustment using th...

Страница 17: ...Unit Install Preparation Review the diagram below to familiarize yourself with the parts included with the unit Please review the following instructions carefully to ensure the unit is prepared proper...

Страница 18: ...tandoffs by hand to form general shape Figure 22 Top Standoff Shape Step 2 There are four 4 nailing flanges to secure the unit to the framing they are assembled flat from the manufacturer Remove the u...

Страница 19: ...position using supplied T 20 screws Initial Installation QUALIFIED INSTALLERS ONLY Step 4 Install heat shield support using four 4 supplied T 20 screws Figure 24 Heat Shield Support Install Figure 25...

Страница 20: ...p 7 Install the supplied non combustible facing board with eight 8 supplied 8 32 x 75 fasteners and a 1 4 inch socket These screws can be found in the manual bag remove them and install the board Line...

Страница 21: ...or installed in a corner There are minimum framing measurements for each situation The basic rough opening should have the following dimensions see Figure 28 The fireplace must be placed on a strong a...

Страница 22: ...mately 1 inch 254mm above the top of the vent pipe Figure 30 Rear Heat Shield Vent Heat Shields All vent configurations require installation of the vertical vent heat shield Remove the three 3 T 20 sc...

Страница 23: ...is activated it is crucial that the chase is vented in accordance to this manual There are a few different options available to frame your CSS Figure 31 Framing Option 1 Initial Installation QUALIFIE...

Страница 24: ...in conjunction with this option 3 76mm Minimum 10 255mm Minimum 6 152mm Minimum Wall Mounted Object Optional Acessory Valance A valance may be desired to accentuate the CSS outlet Consider framing opt...

Страница 25: ...ible materials inside the chase see Figure 34 Note If you wish to construct a similar cutout part way up a tall wall then it is essential to build a false ceiling inside the chase at the desired heigh...

Страница 26: ...room The CSS bleeds heat off the fireplace into the chase as opposed to climbing up the front face This dramatically lowers the front wall temperatures allowing the placement of delicate objects above...

Страница 27: ...6 7 8 9 10 11 12 13 14 M A N T E L H E I G H T M A N T E L D E P T H Minimum Mantle Clearances 8 MANTEL 4 MANTEL 52 51 50 49 48 47 46 44 45 12 MANTEL Diagram 2 Mantel Graph Floor Protection Figure 38...

Страница 28: ...ustible Board supplied 4 102mm Initial Installation QUALIFIED INSTALLERS ONLY Figure 39 Flat Wall Installation Minimum Height to Ceiling Flat Wall Installation These are the minimum allowable dimensio...

Страница 29: ...rd supplied Initial Installation QUALIFIED INSTALLERS ONLY Recess Installation These are the minimum allowable dimensions required to safely operate the fireplace Plan your entire installation before...

Страница 30: ...m allowable framing dimensions required to safely operate the fireplace in a corner install Plan your entire installation before proceeding Figure 41 Corner Installation 3 7 6 m m 3 i n 7 6 m m 2 8 1...

Страница 31: ...follow the venting instructions exactly Deviation from the minimum vertical length can create difficulty in burner start up and sooting Allow several minutes for the flame to stabalize after ignition...

Страница 32: ...ain BDM Pro Form and Duravent flexible direct venting systems Not all rigid venting configurations are allowable when using flex venting Only horizonally terminated applications will work with a verti...

Страница 33: ...composed of combustible material Mantel It is not necessary to install a mantel but if one is desired the guidelines as shown in Initial Installation Mantel Requirements Floor The unit must be raised...

Страница 34: ...Shiplap Extended Tiling Flange 1 2 13mm Drywall 7 8 22mm Mimimum 13 3 8 341mm Supplied Non Combustible Board Extended Tiling Flange 1 2 13mm Supplied Non Combustible Board Standard Cool Surface Syste...

Страница 35: ...s maximum allowable temperature Mantel Only Installaton Always maintain minimum clearances see Figure 45 The total depth of the TV including the wall mount will determine the minimum allowable mantel...

Страница 36: ...r line extended above me ter regulator assembly I 3 ft 91 cm 3 ft 91 cm Radial clearance around service regulator vent outlet Table 4 Vent Termination Clearances Vent Termination Restrictions WARNING...

Страница 37: ...vertical vent pipe Around a horizontal vent pipe the clearance to combustibles should be 3 76 mm above and 1 25 mm on the sides and bottom When combustible materials are directly above a 90 elbow 3 7...

Страница 38: ...table 5DLA30 16 5 to 29 pipe adjustable 5DLS1 1 7 8 to 9 slip length pipe 5DLS2 1 7 8 to 21 slip length pipe 58DVA F6 6EFA 5DT AF6 5DF Flashing 0 12 to 6 12 roof pitch 58DVA F12 6EFB 5DT AF12 5DF12 Fl...

Страница 39: ...n if a 90 elbow is used in the horizontal plane 3 feet 91 4cm must be subtracted from the allowable horizontal run for each 45 elbow 1 feet 45 7cm must be subtracted Restrictor Setting Find the point...

Страница 40: ...Use the corresponding exhaust restrictor setting indicated on the graph See the following section in this manual for restrictor details Your climate and altitude may alter what restrictor is required...

Страница 41: ...horizontal the restrictor level is at its maximum see Figure 51 The proper setting is crucial for an efficient burn and best possible flame appearance It may be necessary to deviate from the recommen...

Страница 42: ...the standoff which provides an air space between the wall and the vent termination The air gap prevents excessive heat from possibly melting the vinyl siding 6 Horizontal pipes must be supported every...

Страница 43: ...Do not pack air spaces with insulation Step 2 Set the fireplace in the desired location Drop a plumb bob down from the ceiling to the fireplace flue exit and mark the location where the vent will pen...

Страница 44: ...2 13 Over 18 12 to 20 12 7 5 2 29 Over 20 12 to 21 12 8 2 44 Figure 55 Height of Vertical Termination Reference Table 7 45 elbows x2 Wall strap Plumber s tape connected to wal strap Figure 57 Use of W...

Страница 45: ...the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water solution after completing the required pressure test TO TEST VALVE P...

Страница 46: ...e the fireplace This model has a millivolt gas control system which uses the pilot flame to generate enough electricity to opeate the main burner External electricity is only required to operate the c...

Страница 47: ...408 WHITE WHITE BLACK WHITE BLACK Initial Installation QUALIFIED INSTALLERS ONLY Figure 60 Convection Fan Wiring Diagram Convection Fan Wiring Use this wiring diagram to diagnose any problems relating...

Страница 48: ...l can irritate your skin Take care not to damage the liners as they are very fragile and can chip easily If handeling porcelain liners it is still a good idea to wear gloves as the oils from your fing...

Страница 49: ...p easily If any logs arrive damaged please contact your ENVIRO dealer for replacement LOG 1 LOG 8 LOG 7 LOG 4 LOG 6 LOG 5 LOG 3 LOG 2 VERMICULITE LOG 9 Step 2 Place Log 2 on the front burner below Log...

Страница 50: ...socket of Log 3 and the right side touching Log 2 Step 6 Rest Log 7 on top of Log 4 and on the edge of the ember bed between the grate arms Do not obstruct burner ports in highlighted area Step 7 Rest...

Страница 51: ...51 Step 8 Place Log 8 on top of Log 1 using the pin with the bottom on the grate Step 9 Place Log 9 on top of Log 1 using the pin with the bottom on the grate Secondary Installation...

Страница 52: ...ilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure...

Страница 53: ...EC 039A 12 PVC Wire Clip 50 3614 13 PSE 4 Way Pilot 50 3623 14 Door Complete 50 3593 Painted Black Liners 50 3540 Porcelain Liners 50 3437 Brown Brick Liners 50 3411 Herringbone Liners 50 3436 Ledges...

Страница 54: ...54 Parts Diagram 7 8 9 10 11 12 13 14 15 6 16 5 4 3 2 1...

Страница 55: ...55 Notes...

Страница 56: ...een mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over...

Страница 57: ..._________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm y...

Отзывы: