24
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 32: Framing Option 2
Framing Option 2: Sunken Chase (built -out installations) -
This could be considered the most
discreet option when considering the CSS. The chase must be constructed in a way that stops short
of the ceiling, leaving it totally vented above. Minimum framing dimensions must be followed when
constructing this option and not to deviated from them when using combustible materials. Consider
Optional Accessory: Valance
to work in conjunction with this option.
3"
76mm
Minimum
10"
255mm
Minimum
6"
152mm
Minimum
Wall Mounted Object
Optional Acessory: Valance -
A valance may be desired to accentuate the CSS outlet. Consider
framing option 1 or 2 to utilize the valance feature. This is an optional decorative feature that covers
up the CSS outlet gap. Minimum opening and valance dimensions must be followed to ensure safe heat
dissipation. Combustible materiel is acceptable when constructing the valance. It is acceptable to wrap
the valance around the three sides of a built out chase (Option 2).
Minimum
4"
102mm
1"
25mm
Maximum
Minimum
10"
254mm
6"
152mm
Minimum
3"
76mm
6"
152mm
Minimum
Wall Mounted Object
Figure 33: Valance Install