8. Re-install the firebox door, then the safety screen. 
9. Run the unit for 15 minutes then adjust the venturi as neededusing the door tool. Figure 51 above 

depicts what the burn and flame appearance shoud look like when the log set is properly installed 

and venturi adjusted.

 

When re-lighting the fireplace for the first time since the log set has been installed/replaced, watch 

for ignition at ALL the burner ports.  If a long delay is noticed, turn the appliance off and wait for it to 

cool down.  Then remove the glass and make sure none of the burner ports are blocked.

Maintenance:

 Once a year, the logs should be removed and checked for deterioration or large amounts 

of soot.  A small amount on the bottom side of the logs is normal.  Remove and replace the logs in the 

same manner described above.

If new logs are required, contact your nearest ENVIRO dealer.

Never operate the fireplace with the glass door removed.

Secondary Installation

Figure 51.  Proper Installation & Flame Appearance

Содержание EX32

Страница 1: ...sing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 400...

Страница 2: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Massachusetts in...

Страница 3: ...must be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFP...

Страница 4: ...16 Cleaning the Glass 17 Cleaning the Firebox 16 Replacing the Glass 17 Check Pilot and Burner Flames 17 Burner Removal 18 Ember Lights Bulb Replacement 19 Top Light Bulb Replacement 19 Fuel Conversio...

Страница 5: ...Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permane...

Страница 6: ...the bottom of the unit Dimensions Install Depth The EX32 has a minimum install depth of 16 406mm The table below shows what depth of install is required with each surround panel Table 1 Install Depths...

Страница 7: ...4 1022mm Depth Bottom 4 112mm Top 3 13 16 97mm 3 11 16 94mm Table 3 Elite Surround Options Surround Borderview Plus Borderview Plus Height 26 125 665mm 26 125 665mm Width 40 1016mm 40 1016mm Surround...

Страница 8: ...to light the pilot by hand 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you do...

Страница 9: ...ch is a safety hazard Contact the dealer if there is any concern about the venturi adjustment Figure 4 Adjusting the venturi air setting The venturi adjustment lever is located on the right side of th...

Страница 10: ...is powered by three 3 AAA type batteries A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 5 6 Figure 5 Prof...

Страница 11: ...ith wiring harnesses The IFC is mainly powered by 120 VAC but can also run off a battery backup four 4 AA type batteries for shorter periods of time The IFC accepts commands via radio frequency from t...

Страница 12: ...nstructions Turn off the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature and Icon see Figure 9 A single beep from the IFC confirms rec...

Страница 13: ...Maximum Flame Level Fan Control The EX32 comes with a convection fan that can be controlled with the Transmitter The fan speed can be adjusted thorugh six 6 speeds To control the fan press the MODE k...

Страница 14: ...the IFC will confirm the command has been received The top light is most noticable when the flame is set to the lowest setting It can also be left on when the flame is off see Remote Flame Control se...

Страница 15: ...iance burner when operating the remote system Operating Instructions WARNING Shock Hazard Can cause severe injury or death This device is powered by line voltage Do not try to repair this device In no...

Страница 16: ...ainted Surfaces Painted surfaces should be periodically wiped with a damp cloth when the unit is cool Figure 19 A Door Spring Latch Locations The glass door of the fireplace is retained at the top by...

Страница 17: ...the dealer Check the logs for deterioration or large amounts of soot a small amount on the logs is normal Replace the logs and embers as in the Secondary Installation Log Set and Ember Installation s...

Страница 18: ...tenance and Service Glass Door Removal 2 Carefully remove the log set and embers as shown in Secondary Installation Log Set Installation 3 Remove the four log tray screws using a T20 screwdriver then...

Страница 19: ...transmitter turn off the ember lights see page 13 2 Remove the burner as outlined in Maintenance and Service Burner Removal 3 Remove the light tray by simply lifting up and out 4 Replace the burnt out...

Страница 20: ...ontact your dealer distributor or courier company to have them replaced before starting this installation Maintenance And Service Conversion Kit Installation 1 Turn the unit off by pressing the ON OFF...

Страница 21: ...led at an altitude higher than 2000ft 610m it is required to de rate the unit accordingly In the USA The appliance may be installed at higher altitudes Please refer to your American Gas Association gu...

Страница 22: ...th Fireplace Dimensions 28 711 mm 18 1 2 470 mm 20 508 mm 16 406 mm NOTE Space must be provided for gas line on right side of unit for servicing purposes Venting WARNING This appliance has been design...

Страница 23: ...eplace prior to installation Initial Installation QUALIFIED INSTALLERS ONLY The ENVIRO EX32 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the Nat...

Страница 24: ...installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and local building codes and has been constructed of non combustible materi...

Страница 25: ...rminal Slide the flex liner onto the vent terminal and secure with three 3 sheet metal screws evenly spaced 9 Place a bead of high temperature silicone on the Table 7 Vent termination clearances Minim...

Страница 26: ...ace a bead of high temperature silicone on the intake collar of the fireplace slide the 3 76mm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws evenly spaced 13...

Страница 27: ...floor is prohibited The included label plate shown below must be permanently attached inside the cavity of the fireplace in a visible location WARNING This fireplace has been converted for the use wit...

Страница 28: ...LLERS ONLY Figure 33 Wiring Schematic IFC Main Harness Transmitter TMFLSA 885 Gas Valve IPI Pilot Convection Fan Proflame 2 System Wiring Diagram Main On Off Power Cord To Battery Holder Flame Sensor...

Страница 29: ...I D hose over pressure tap system Check pressures using a manometer When finished release pressure remove hose tighten set screw Gas Line Connection Prior to installation consult your local authoriti...

Страница 30: ...18 KW NEVER USE AN OPEN FLAME FOR LEAK TESTING Adjusting The Pilot Flame The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted The pilot flame should envelope t...

Страница 31: ...tions excluding 4 sided and it may also be used with the trimmable Surround The Base Shelf and Riser are sold separately Installation 1 If unit is running turn it off and allow it to cool completely 2...

Страница 32: ...beginning this installation Height Width 3 Sided Surround 25 635 mm 39 7 8 1013 mm 4 Sided Surround 31 1 2 800 mm 39 7 8 1013 mm Table 10 Surround Dimensions Please check components supplied with this...

Страница 33: ...rect measurements of offset and remove any sharp edges 5 The panel can be touched up with a high temperature metallic black paint available from your dealer INSTALLATION 1 Install the two Trimmable Pa...

Страница 34: ...2 Next install the back log as shown in Figure 45 and position it all the way to the right The right front corner will rest on the triangle support when installed correctly Then fill the front ember...

Страница 35: ...ond Right Top Logs Figure 50 Nuggets and Ember Wool 6 Next Install the left and second right top log as shown in Figure 49 Note the locating notches on the bottom side of both logs areas highlighted T...

Страница 36: ...at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a year...

Страница 37: ...will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional I...

Страница 38: ...type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot f...

Страница 39: ...r temperature Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases Check to se...

Страница 40: ...09 Ledgstone Liner Set 50 2774 Porcelain Liner Set 50 2427 15 EX32 EX35 Pilot Shield 50 3514 16 EX32 Stainless Steel Baffle 50 3527 17 Top Light Assembly 50 3516 18 Fan Only 50 2493 19 Proflame 2 IFC...

Страница 41: ...41 Parts Diagram Components 16 12 11 10 9 8 7 15 6 23 14 17 3 4 5 18 22 19 20 21 2 1 13 24 25 26 27...

Страница 42: ...42 Notes...

Страница 43: ...ty screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from...

Страница 44: ...__________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIR...

Отзывы: