Figure 4: Gas Valve.

Figure 3: Pilot Burning.

7

• 

There  is  a  separate  venturies  for  each  burner, 

see Figure 4.

• 

Remove one screw from the cover plate located 

below the ash shelf and loosen the other screw 

(do not remove) swing the cover plate out of the 

way and tighten screw down to hold it in place.

• 

With along screwdriver rotate spring clips to open 

or close the venturies to the desired setting.

The venturies allows the amount of air coming into 

the fireplace to be adjusted in order to accommodate 

different climates and venting arrangements. Start 

Operating Instructions

Gold bar

Screwdriver

Rear log holder

Front log holder Ember tray & 

front burner

Venturies

Door

Rear burner

Air shutter cover plate

Figure 4: Venturi Adjustment.

the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports 

are plugged. Let the fireplace burn for roughly fifteen9minutes and then examine the flames, compare 

the flames to Figure 16.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. 

If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, 

the fireplace is getting too much air. Therefore, the venturies should be closed slightly until the correct 

flames are achieved.  Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. 

Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct 

flames cannot be attained, turn off the gas and contact the dealer.

Warning:

 Incorrect  venturi adjustment may lead to improper combustion, which is a safety hazard. 

Contact the dealer if there is any concern about the venturi adjustment.

n

oRmaL

 s

ounDs

 D

uRing

 o

peRation

:

Table 1: Normal Sounds

Component

Sound & Reason

EG40

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The 

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

a

Djusting

 t

he

 V

entuRies

:

Содержание EG40 BV NG

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...oval 9 Replacing The Blower 9 Fuel Conversion 10 Initial Installation 12 Preparation For Installation 12 Clearances to Combustibles 12 Flue Gas Spill Switch 12 Venting 13 Manufacturer s General Ventin...

Страница 4: ...UDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...rs and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and other...

Страница 10: ...re explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The...

Страница 11: ...re 11 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installe...

Страница 12: ...circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation air must not be obstru...

Страница 13: ...ING A SEPARATE SOLID FUEL BURNING APPLIANCE Manufacturer s General Venting Guidelines This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 g...

Страница 14: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 15: ...tal run The venting should never slope down a minimum inch 0 6 cm rise is needed for every 2 ft 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of...

Страница 16: ...ing instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet DO NOT c...

Страница 17: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 18: ...ly See Figure 20 or 23 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 19: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 20: ...low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line...

Страница 21: ...ow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B...

Страница 22: ...302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1...

Страница 23: ...23 Parts Diagram Chassis 16 1 29 22 2 15 23 19 20 13 18 8 14 EG 40 Body Chassis July 2004...

Страница 24: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 24...

Страница 25: ...ctly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance A proof of original purchase must be provided by you or the dealer Exclusions An expanded...

Страница 26: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: