Enviro EG40 BV NG Скачать руководство пользователя страница 6

Operating Instructions

FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.

L

ighting

 i

nstRuctions

:

6

1.   STOP! Read the safety information above on this label.
2.   Turn off all electrical power to this appliance.
3.   Turn off the gas control knob clockwise            to the off position.
4.   Open door. Wait fIve (5) minutes to clear out any gas. Close 

      door. If you smell gas STOP! Follow “B” in the  above safety  

      information. If you do not smell gas go to the next step.
5.   Find pilot-located to the right between the front and rear burner.
      Turn the gas control knob counter-clockwise             to  

      “PILOT”. Push the gas control in fully and hold, keep knob 

      depressed for about 30 seconds after the pilot is lit. 

      Release knob. If pilot goes out, repeat steps 4 

      through 5.

CAUTION:

Hot while operating. Do not touch, severe burns may result. Keep children, 

clothing, furniture, gasoline or other  flammable vapors away.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

 PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 A)  This appliance is equipped with a pilot, which must be lit by 
      hand by following these instructions exactly. 
 B) BEFORE LIGHTING smell all around the appliance area for
     gas and next to the floor because some gas is heavier than air

     and  will settle on the floor.    
   WHAT TO DO IF YOU SMELL GAS:

  Do not try to light any appliance. Do not touch any electrical  

  switch: do not use any phone in your building. Immediately call 

  your gas supplier from a neighbor's phone. Follow  the gas 

  suppliers instructions. If you cannot reach your gas supplier, call 

  the fire department.

C)   Use only your hand to push in or turn the gas control knob; 

       NEVERuse tools. If the knob will not push in or turn by hand, 

       do not try to repair it. Call a qualified service technician.  

       Force or attempted repair may result in a fire or explosion.
D)   Do not use this appliance if any part has been under water.
       Immediately call a qualified service technician to inspect the 

       appliance and to replace any part of the control system and  

       any gas controlwhich has been under water.     

LIGHTING INSTRUCTIONS

 WARNING: this gas valve has a lockout device, which will not 

   allow thepilot burner to be relit until the thermocouple has 

   cooled. If the knob doesdoes not pop up when released, stop 

   and immediately call your service technician or gas supplier. 

   If the pilot does not stay lit after several tries, turn the gas

   control knob  to “OFF” and call your service technician or 

   gas supplier.    
6.   Turn the gas control knob counter clockwise            to the 
      “ON” position. Flip the burner switch to “ON” THEN  TURN

      THE “HI/LOW” knob to the 

      desired setting.
7.   Turn on the electrical 
      power to the unit.

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”

2. Turn the gas control knob clockwise             to the “OFF” position.

3. Turn off all electrical power to the appliance if service is to 

     be performed.

CAUTION:

 Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a 

licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion 

and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: 

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. 

Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, 

service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must 

be performed by a qualified installer, service agency, or the gas supplier.

O

L I

T

P

TP

 T

H

    

  T

P

    

   T

H

IN

    

    

    

   O

UT

H

I

LO

N

OF

O

F

LI

P

T O

Figure 2: Lighting Instructions.

Содержание EG40 BV NG

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...oval 9 Replacing The Blower 9 Fuel Conversion 10 Initial Installation 12 Preparation For Installation 12 Clearances to Combustibles 12 Flue Gas Spill Switch 12 Venting 13 Manufacturer s General Ventin...

Страница 4: ...UDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...rs and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and other...

Страница 10: ...re explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The...

Страница 11: ...re 11 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installe...

Страница 12: ...circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation air must not be obstru...

Страница 13: ...ING A SEPARATE SOLID FUEL BURNING APPLIANCE Manufacturer s General Venting Guidelines This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 g...

Страница 14: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 15: ...tal run The venting should never slope down a minimum inch 0 6 cm rise is needed for every 2 ft 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of...

Страница 16: ...ing instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet DO NOT c...

Страница 17: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 18: ...ly See Figure 20 or 23 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 19: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 20: ...low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line...

Страница 21: ...ow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B...

Страница 22: ...302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1...

Страница 23: ...23 Parts Diagram Chassis 16 1 29 22 2 15 23 19 20 13 18 8 14 EG 40 Body Chassis July 2004...

Страница 24: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 24...

Страница 25: ...ctly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance A proof of original purchase must be provided by you or the dealer Exclusions An expanded...

Страница 26: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: