background image

Maintenance And Service

F

ueL

 c

onVeRsion

:

Figure 8: Removing 

valve cap.

5.  Convert the burner orifice(s):

a) Remove the main burner orifice with a ½ inch deep socket.
b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice 

threads before installing into the brass elbow. 

c) Install the new orifice(s) from the kit into the brass elbow.

6.  Convert the pilot injector:

a) Pull the pilot hood straight up to access the pilot injector. 
b) Using a 

5

/

32

” or 4 mm Allen key, remove the pilot injector.

c) Install the new pilot injector supplied with this conversion kit.  Simply screw 

the new injector inside the pilot hood using the Allen key, 

d) Reinstall the hood by placing the hood on the assembly, line up the key 

way, and snap into place.

10

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing. 

Warning:  This conversion kit shall be installed by a qualified service agency in accordance 

with the manufacturer’s instructions and all applicable codes and requirements of the 

authority  having  jurisdiction.  If  the  information  in  these  instructions  is  not  followed 

exactly, a fire, explosion or production of carbon monoxide may result causing property 

damage, personal injury or loss of life. The qualified service agency is responsible for 

the  proper  installation  of  this  kit.  The  installation  is  not  proper  or  complete  until  the 

operation  of  the  converted  appliance  is  checked  as  specified  in  the  manufacturer’s 

instructions supplied with the kit.

Kit Parts List:

 

1 - Orifice (NG - Front #48 DMS & Rear #43 DMS or LP - Front #56 DMS & Rear #54 DMS)
1 - Pilot Injector (NG  0.62 mm; LP  0.35 mm)
1 - Installation instruction sheet 

 

 

 

1 - Conversion label

Carefully  inspect  all  parts  supplied  with  this  conversion  kit.  If  any  parts  have  been  damaged  or  are 

missing, contact your dealer, distributor or courier company to have them replaced before starting this 

installation.

Conversion Kit Installation:

1.  Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off 

valve upstream of the unit.  CAUTION: The gas supply must be shut off prior to disconnecting the 

electrical power and before proceeding with the conversion. Allow the valve and unit to cool down 

to room temperature.

2.  Remove the glass as shown in the 

M

aintenance

 

and

 S

ervice

 - O

pening

 t

he

 d

OOr

3.  Carefully remove the log set and ember material if they are installed.
4.  Remove the burner as shown in the 

M

aintenance

 

and

 S

ervice

 - B

urner

 r

eMOval

Содержание EG40 BV NG

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...oval 9 Replacing The Blower 9 Fuel Conversion 10 Initial Installation 12 Preparation For Installation 12 Clearances to Combustibles 12 Flue Gas Spill Switch 12 Venting 13 Manufacturer s General Ventin...

Страница 4: ...UDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...rs and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and other...

Страница 10: ...re explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The...

Страница 11: ...re 11 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installe...

Страница 12: ...circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation air must not be obstru...

Страница 13: ...ING A SEPARATE SOLID FUEL BURNING APPLIANCE Manufacturer s General Venting Guidelines This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 g...

Страница 14: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 15: ...tal run The venting should never slope down a minimum inch 0 6 cm rise is needed for every 2 ft 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of...

Страница 16: ...ing instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet DO NOT c...

Страница 17: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 18: ...ly See Figure 20 or 23 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 19: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 20: ...low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line...

Страница 21: ...ow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B...

Страница 22: ...302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1...

Страница 23: ...23 Parts Diagram Chassis 16 1 29 22 2 15 23 19 20 13 18 8 14 EG 40 Body Chassis July 2004...

Страница 24: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 24...

Страница 25: ...ctly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance A proof of original purchase must be provided by you or the dealer Exclusions An expanded...

Страница 26: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: