Trouble Shooting

20

Problem

Possible Cause

Solution

The  main  burner 

does  not  ignite 

when called for.

The gas valve may not be on.

• Check that the gas control knob is in the “ON” position.

Thermostat is not calling for 

heat.

• Adjust the thermostat several degrees above ambient temperature.

Problem with gas valve.

• Use a DC voltmeter to measure the voltage across the TPTH and 

TP terminals. Main operator voltage: Open circuit ≥ 325mV Closed 

circuit ≥ 100mV

• If voltage is not present, check the control circuit for proper 

operation.

• If proper control system voltage is present, replace the gas control.

Spark will not 

light the pilot 

after repeatedly 

pressing the 

spark ignitor.

Defective piezo ignitor.

• Check connections to ignitor.

• If ignitor connections are good but no spark, replace ignitor.

Broken spark electrode.

• Check for broken ceramic insulation, replace electrode if broken.

Misaligned spark electrode.

• If spark is not arcing from electrode to pilot, loosen the screws on the 

pilot base adjust and tighten.

Pilot will not 

remain lit.

Problem with thermocouple 

circuit.

• Check for proper connection of the thermocouple to the rear of the 

valve. If loose, fully tighten.

• Check pilot for full flame impingement around thermocouple.  If flame 

is too small, check gas pressure, adjust pilot rate screw, check pilot 

head for damage.

• Check thermocouple voltage at valve. It must be greater than 5 mV.  

If low, replace thermocouple.

Air in gas line (pilot dies while 

knob is depressed).

• Bleed line.

• Check gas line pressure.

• Contact dealer.

Burners will not 

remain lit.

Problem with thermopile 

circuit.

• Check gas line pressure .

• Check for flame impingement on thermopile. If low, see “Pilot will not 

remain lit”.

• Check thermopile for minimum of 300 mV when burner is switched 

on.

• Check wiring to thermostat for breaks.

BV ONLY: 

Check for spillage at draft hood that may trip spill switch

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

Improper vent configuration

• Check vent configuration with manual.

Terminal may be recirculating 

flue gases

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

Flames are 

burning “dirty” or 

sooting

Flame impingement

• Check log positioning.

• Increase primary air by opening the venturi shutter and/or by 

opening the vent restrictor.

See also “Burners will not remain lit.”

Remote control 

doesn’t work

Problem with the remote

• One or more of the batteries are dead. See remote control 

instructions.

Problem with fireplace

• The on/off switch is turned to OFF.

• The gas control valve is turned to PILOT or OFF.

• The pilot has gone out.

BV ONLY: 

Insufficient air 

for combustion

• Air tight house.

• A vacuum in room due to 

other air-moving device.

• Supply make up air to the unit.

Содержание EG40 BV NG

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...oval 9 Replacing The Blower 9 Fuel Conversion 10 Initial Installation 12 Preparation For Installation 12 Clearances to Combustibles 12 Flue Gas Spill Switch 12 Venting 13 Manufacturer s General Ventin...

Страница 4: ...UDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...rs and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and other...

Страница 10: ...re explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The...

Страница 11: ...re 11 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installe...

Страница 12: ...circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation air must not be obstru...

Страница 13: ...ING A SEPARATE SOLID FUEL BURNING APPLIANCE Manufacturer s General Venting Guidelines This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 g...

Страница 14: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 15: ...tal run The venting should never slope down a minimum inch 0 6 cm rise is needed for every 2 ft 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of...

Страница 16: ...ing instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet DO NOT c...

Страница 17: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 18: ...ly See Figure 20 or 23 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 19: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 20: ...low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line...

Страница 21: ...ow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B...

Страница 22: ...302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1...

Страница 23: ...23 Parts Diagram Chassis 16 1 29 22 2 15 23 19 20 13 18 8 14 EG 40 Body Chassis July 2004...

Страница 24: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 24...

Страница 25: ...ctly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance A proof of original purchase must be provided by you or the dealer Exclusions An expanded...

Страница 26: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: